12.07.2015 Views

SAFA Ramp Inspections - Code7700

SAFA Ramp Inspections - Code7700

SAFA Ramp Inspections - Code7700

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SAFA</strong> <strong>Ramp</strong> Inspection ProceduresGuidance materialInspectionItem<strong>Inspections</strong> Item Title Inspecting InstructionsB04 Hand Fire extinguishers Check if the installed extinguisher(s) is at the indicated location and easily accessible.Check if the installed extinguisher is correctly secured in its bracket.Check if the installed extinguisher(s) is marked with the appropriate operating instructions.Check if the installed extinguisher(s), including the extinguishing agent release mechanism, is serviceable – check pressuregauge (if installed), check expiration date (if any). If considerably low weight, consider it unserviceable.Note: Often HFEs in excess of those required (by MEL provisions) may be U/S, however in such a case, check against theMEL to verify compliance with the applicable (M) and/or (O) procedures. If the latter MEL actions have not been applied,a finding should be raised using the "detection / reporting / assessment of significant technical defect" procedure (seeChapter 4.2 above).Note: ICAO does not require hand fire extinguishers to have an expiration (or next check) date. Operators may employ varioussystems to monitor the condition of the extinguishers. An extinguisher without a date does not necessarily constitute afinding. However, if the expiry date (or next inspection date) is overdue, consider it as unserviceable.InspectionItemStd. Cat. Std. ref. Standard’s Text Pre-described Finding PDF code Instructions for completingthe detailed descriptionB04 I 2 A8-IIIA-8.3A8-IIIB-6.3A8-V-6.3Prescribed safety and survival equipment that the crewor passengers are expected to use or operate at thetime of an emergency shall be reliable, readilyaccessible and easily identified, and its method ofoperation shall be plainly marked.HFE not at indicatedlocationB04-01B04 I 2 A8-IIIA-8.3A8-IIIB-.6.3A8-V-6.3Prescribed safety and survival equipment that the crewor passengers are expected to use or operate at thetime of an emergency shall be reliable, readilyaccessible and easily identified, and its method ofoperation shall be plainly marked.B04 I 3 A6-I-.2.2(b)(2) An aeroplane shall be equipped with:b) portable fire extinguishers of a type which, whendischarged, will not cause dangerous contamination ofthe air within the aeroplane. At least one shall belocated in:HFE not marked with theappropriate operatinginstructionsHFE empty,unserviceable or missing(outside MEL limits)B04-02B04-03 Indicate the particulars ofthe situation observed2) each passenger compartment that is separate fromthe pilot's compartment and that is not readilyaccessible to the flight crew;Note.- Any portable fire extinguisher so fitted in<strong>SAFA</strong> Coordination Section Page 133 of 217© European Aviation Safety Agency, 2012 V 2.0

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!