12.07.2015 Views

SAFA Ramp Inspections - Code7700

SAFA Ramp Inspections - Code7700

SAFA Ramp Inspections - Code7700

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SAFA</strong> <strong>Ramp</strong> Inspection ProceduresGuidance materialInspectionItem <strong>Inspections</strong> Item TitleInspecting InstructionsA15 Hand Fire Extinguishers Check if the installed extinguisher(s) is at the indicated location and easily accessible.Check if the installed extinguisher(s) is marked with the appropriate operating instructions.Check if the installed extinguisher(s) (including the extinguishing agent release mechanism) is serviceable (check pressuregauge (if installed), check expiration date (if any)). If considerably low weight consider unserviceable.Note: Often HFEs in excess of those required (by MEL provisions) may be U/S, however in such a case, check against the MELto verify compliance with the applicable (M) and/or (O) provisions. If the latter MEL actions have not been applied, a findingshould be raised using the "detection/reporting/assessment of significant technical defect" procedure (see chapter 4.2 ofthe ramp inspection procedure).Note: ICAO does not require hand fire extinguishers to have an expiration (or next check) date. Operators may employ varioussystems to monitor the condition of the extinguishers. An extinguisher without a date does not necessarily constitute afinding. However, if the expiry date (or next inspection date) is overdue, consider as unserviceable.InspectionItemStd. Cat. Std. ref. Standard’s Text Pre-described Finding PDFcodeA15 I 2 A6-I-6.2.2b An aeroplane shall be equipped with:b) portable fire extinguishers of a type which, whendischarged, will not cause dangerous contamination of the airwithin the aeroplane. At least one shall be located in:1) the pilot's compartment; and2) each passenger compartment that is separate from thepilot's compartment and that is not readily accessible to theflight crew;Note.- Any portable fire extinguisher so fitted in accordancewith the certificate of airworthiness of the aeroplane maycount as one prescribed.Instructions forcompleting the detaileddescriptionHFE not at indicated location A15-01 Provide furtherinformation as to wherethe HFE was found andwhere it is its indicatedlocationA8-IIIA-8.3A8-IIIB-6.3 A8-V-6.3Prescribed safety and survival equipment that the crew orpassengers are expected to use or operate at the time of anemergency shall be reliable, readily accessible and easilyidentified, and its method of operation shall be plainlymarked.A15 I 2 A6-I-6.2.2b An aeroplane shall be equipped with:b) portable fire extinguishers of a type which, whendischarged, will not cause dangerous contamination of the airwithin the aeroplane. At least one shall be located in:1) the pilot's compartment; andHFE not marked with theappropriate operatinginstructionsA15-02<strong>SAFA</strong> Coordination Section Page 81 of 217© European Aviation Safety Agency, 2012 V 2.0

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!