13.07.2015 Views

Orion AquaMate 7000 Vis Orion AquaMate 8000 UV-Vis - Daigger

Orion AquaMate 7000 Vis Orion AquaMate 8000 UV-Vis - Daigger

Orion AquaMate 7000 Vis Orion AquaMate 8000 UV-Vis - Daigger

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3 AccessoriesCell Holders and Cell Holder AccessoriesIf the 6-Position Cell Holder has been installed, it will initialize it to the “B” position. After ithas initialized the cell changer, the instrument will display the data collection screen for thetest.Note If, while in this screen, you remove the cell changer and press Run Sample, theinstrument will display “Fatal Error: 8 Press Esc to return to main menu.”Pressing Esc returns you to the parameter menu screen of the test. Press Run Test and theinstrument will now display the message, “Calibrating and Checking Turret, Please Wait”while it attempts to initialize the cell positioner at the Blank position.If the cell changer is still not in the sample compartment, the instrument will display“Error, Single Cell Holder Found. Use Single Cell Holder?”Either press Cancel Change and reinstall the cell changer or press Accept Change tocontinue with using the single cell holder.To prevent the Fatal Error whenever removing the cell changer, always return to either themain menu or the test parameter menu of the test before removing the cell changer.Changing Cell HoldersTo:• use long pathlength cells (cylindrical or rectangular)• use test tubes• measure solid samples in the filter holder• regulate sample temperature via an external liquid recirculatoryou must install the appropriate cell holders. The 6-Position Cell Holder installed in thespectrophotometer can easily be removed to install other accessory cell holders. See“Removing the 6-Position Cell Holder and the Single Cell Holder” on page 17.Installing the 6-Position Cell Holder and the Single Cell HolderTo install the 6-Position Cell Holder and the Single Cell Holder1. Open the sample compartment door and let it rest on its hinge.2. With one hand, carefully lower the cell holder straight down into the samplecompartment.Thermo Scientific <strong>Orion</strong> <strong>AquaMate</strong> <strong>7000</strong> <strong>Vis</strong> and <strong>Orion</strong> <strong>AquaMate</strong> <strong>8000</strong> <strong>UV</strong>-<strong>Vis</strong> 15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!