21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Control</strong> Valve – request for quotation11Please copy, fill out and send to your nearest Bürkert facility – on p. 410 you will find a Bürkert address listor visit us at www.burkert.comCompanyContact personCustomer NoDepartmentAddressPostcode/TownTel./FaxE-mail= mandatory fields to fill out Quantity Required delivery dateOperating dataSite of controlMeasuring and control taskPipelinePipe materialProcess mediumType of mediaFlow rate (Q, QN, W) 1)DNPNLiquid Steam GasMin Standard Max unitTemperature at valve inlet T1Absolute pressure at valve inlet P1Absolute pressure at valve outlet P2Steam pressure PvKinematic viscosity (ν)Dynamic viscosity (η)Standard densityMax. sound level acceptedValve featuresmm 2 /s or cStmPa.s or cPKg/m 3DB (A)1) standard unitLiquid Q = m 3 /h; Steam W = Kg/h; Gas QN = Nm 3 /h<strong>Control</strong> valve typeBody materialSurface finish 2)Seat sealing materialNominal pressureNominal sizeType of connectionStandard connectionFunctionPilot pressure2) Only diaphragm valvePNDNGlobe Angle seat Diaphragm Ball Valve Butterfly OtherStainless steel PVC PP PVDF OtherinternalexternalMetal PTFE EPDM 2) FKM 2)Flange Socket union Welded Int. thread Ext. thread Tri-Clamp ®ISO DIN ANSI JIS OtherNC NO Double-actingmin.max.Positioner / <strong>Control</strong>lerType 1067 - 3 wire Type 8630- 3 wire Type 8635- 2 wireValve mountedPower supply 24 VDCCommunicationSetpoint/output analog signalRemote versionPositioner versionInput0/4 - 20 mA / 0-10 VOutput4 - 20 mAorBinaryPID <strong>Control</strong>ler version 3)Input measuring signal 4 - 20 mAPower supply 24 VDCCommunicationSetpoint/output analog signalor via BUSProfibus DPDevice NetPositioner versionInput0/4 - 20 mA / 0-5/10 VOutput4 - 20 mAor/andBinaryPID <strong>Control</strong>ler version 3)Input measuring signal4 - 20 mA / Pt100 / FrequencyStandardEEx iaPower supply 24 VDC via setpoint or BUSCommunicationSetpoint/output analog signalor via BUSProfibus PAHartPositioner versionInput4 - 20 mAOutputPID <strong>Control</strong>ler version 3)Input measuring signal4 - 20 mA4 - 20 mAor/andBinary3) same setpoint for Input and Output signal as for Positioner versionInductive proximity switch 1 2 Inductive proximity switch 1 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!