21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

261Safety barrierfor Type SE30 Ex sensor• 2 or 4 channels, intrinsic safety digital inputs:proximity detectors NAMUR, contacts...• Rail mount on hat profile 35 mm• All connections by removable screw terminalSE30 ExSpecificationsDigital inputsIntrinsic safety inputsNon intrinsic safety recopyoutputsCut-off power:Collector cut-off power:Selection of the sensortypeSelection of the logicFault detectorEach of the 4 x intrinsic safety inputscan be configured independently for acontact or a proximity detector NAMURas per DIN 19234.Proximity detector NAMUR as perDIN 19234 or free potential contacts,relays, pressure or temperature switchesor push buttons in hazardous area.According to the type of sensor and thechosen logic: a green LED on the frontpanel displays a free-potential contactfor each channel without common wire.230 V AC - 0.5 A - 120 VA15 V - 60 mA - 0.9 VA - 350 HzInductive / capacitive intrinsic safetycertified NAMUR proximity detector orfree-potential contacts.By a mini-DIP choice of the activeoutput in presence or lack of target(proximity detector) or when contact isNO (Normally Open) or NC (NormallyClosed).For all inputs configured as NAMUR,all models is provide with fault detector(broken line or short-circuit). In faultycase, the green front LED switches off,the contact of the defective channelopens and the red LED correspondingto the defective channel switches on.Other channels are not affected.Power supply 24 V DC ±10%230 V AC ±10%1 front panel yellow LED is “ON” whensupply is activeConsumption5 VASpecifications (continued)ConnectionsClassification for explosiveareasAmbient TemperatureOperatingStorageDimensional andmechanicalConditions of installationMounting on DIN rail:Mounting inside a cabinet:All connections by removable screwterminals. Supply distribution by meansof a flat cable from one unit to thenext one. This flat cable is in standarddelivery.Intrinsic safety associated apparatus.It must be installed in safe area andconnected to materials installed inzone 0, 1 or 2 - Gas (G)or in zone 20, 21 or 22 - Dust (D)Classification according to ATEX 94/9/CE:I/II (M1)/(1) G/D [EEx ia] IICSafety parameters see EC-type certificateLCIE 00ATEX 6034X-20 to +60 °C-20 to +50 °C (recommended)-40 to +80 °CHousing for symmetric DIN rail (hat profile35 mm as per standard NFC63015 / EN50022) -Depth:120 mm; Width on rail 29.5 mm;- Height: 90 mm - 145 mm overallincluding space for cables. Minimaldistance between rails: 180 mm.must take into account thermal dissipationand risk of overheating generated byhousings installed side by side. In case of ahigh concentration inherent safety barrier,we recommend to leave a free space of10 mm between each group of 8 units(horizontal rail) and between each group of4 units (vertical rail).It is recommended to close the electricalcabinet and to ensure a circulation of freshair even by means of an air conditioner tokeep the inside temperature at the levelcompatible with the recommendedoperating temperature among the units.SensorsOrdering chart for Safety barrierfor Type SE30 Ex sensorClassificationsfor explosiveareasVoltage supplyOutputNumber ofchannelsItem no.24 V DC open collector, 15 V DC, 60 mA 2, with NAMUR input 553 456ATEX 94/9/CE 4, with NAMUR input 553 457I/II (M1)/(1) G/D [EEx ia] IIC 230 V AC open collector, 15 V DC, 60 mA 2, with NAMUR input 553 4584, with NAMUR input 553 459Subject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!