21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

290Electromagnetic flow transmitter8045Type 8045 can be combined with...• Sensor in solid-state technology(no moving parts)• Shows both flow rate and volume• Simulation: all output signals providedwithout the need for real flow• Clean In Place (CIP)• FDA approvedType S020Insertion fittingType 2712Continuouscontrol valveType 8644-PAirlinevalve islandType 2030Diaphragm valvePLCSensorsThe Magflowmeter 8045 is designed for pipes withdiameters ranging from DN 6 to DN 400 and liquidshaving a conductivity > 20 µS/cm.The transmitter has a large display, a keyboard andprovides 4-20 mA, relay and pulse outputs.The version having a stainless steel sensor is designedfor applications with high pressures (PN16)and high temperatures (up to 110 °C).Technical dataPipe diameter DN 6 to DN 400 (see fitting S020, pages 294 to 301)Measurement <strong>range</strong> from 0.02 m 3 /h up to 4500 m 3 /hFlow velocityAccuracy 1)TEACH-INStandard K-factorLinearityRepeatability 1)0.2 to 10 m/s(for measured value from 1 to 10m/s and -20 °C < T° < 130°C)≤ ±2 % o.R.*≤ ±4 % o.R.*±(1% o.R.*+ 0.1% o. F.S.*)≤ 0.25% o.R.*Electrical connection Cable glands M 20 x 1.5Voltage supply cable Shielded; cross section: max. 1.5 mm 2Protection classRelative humidityAltitude max. for operating<strong>Fluid</strong> temperatureAmbient temperatureStorage temperatureMax. fluid pressureConductivityMaterialsHousing, cover / Protection lidFront panel folioWetted partsFittingFinger, electrodesSeal / Electrode holderOperating voltageOutputPulseRelay (programmable)CurrentCurrent consumption* o.F.S. = of Full Scaleo.R. = of ReadingIP 65 with cable gland mounted and tightenedMax. 80%, non condensated2000 m-25 to +110 °C (-13 to 230 °F) (depends on fitting)-10 to +60 °C (14 to 140 °F)-20 to +60 °C (-4 to 140 °F)Max. PN16 (depends on temperature and fitting material,see pressure-temperature chart, page 295)Min. 20 μS/cmPPA, glass fibre reinforced / PSUPolyesterPVC, PP, PVDF, stainless steel 1.4404/316L, brassStainless steel (DIN1.4404)EPDM (FDA agreements) / PEEK (FDA agreements)18-36 V DC (3 wires) - filtered and regulatedprotected against reverse of polarityNPN and PNP, open collector, galvanic insulation, up to36 V DC, 100 mA max., protected against short-circuitsand polarity reversals2 normally open relays, freely adjustable 250 VAC, 3A or30 V DC, 3A (resistive load), max. cutting power of 750 VA(resistive load), Hysteresis thresholds4-20 mA, approx. 500 ms refresh rate;max load: 1300 Ω at 30 V DC, 1000 Ω at 24 V DC,700 Ω at 18 V DCMax. 300 mA1) under reference conditions, i.e. fluid = water, temperatures = 20°C,up and downstream distances respected, adapted dimensions and pipesSubject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!