21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

96<strong>Control</strong> Heads for pneumatically operatedON/OFF Process Valves<strong>Control</strong> Units for ON/OFF Process Valves<strong>Control</strong> HeadsType 1066 Type 8631ON/OFF Process ValvesProcess ValvesType 2030Page 118Type 2031Page 126page 122Type 2032Page 140Type 2033Page 142Type 2000Page 102Type 2012Page 110Bürkert <strong>Control</strong> Heads in short<strong>Control</strong> Head Type 1066 <strong>Control</strong> Head Type 8631Top<strong>Control</strong> ON/OFFThe Type 1066 head is used to convenientlycontrol pneumatic process valves associatedmainly with hygienic processing. The designand scope of functions meets the special requirementsof the food, beverage, pharmaceutical,cosmetic and biotech industries. Electricaland pneumatic control components as wellas position feedback units and optional fieldbus interfaces (AS-Interface or DeviceNet) areintegrated into the control head.Possible scope of functions:• <strong>Control</strong> of process valves- single-acting or double-acting- with 2 or 3-position actuator- with seat lift actuator.• Position feedback with max. three adjustableinductive limit switches or two microlimit switches• Electrical control of control head, optionallyvia multipole (parallel wiring) or field businterface (AS-Interface or DeviceNet)• Relief valve for burst protectionThe Type 8631 Top<strong>Control</strong> ON/OFF headperforms the task of completely automatingpneumatically operated process valves. Mechanicalmounting and pneumatic couplingto the process valve result in a unit that isboth visually pleasing and functionally compact.Valve position feedback and pneumaticactuation can also be integrated into commonfieldbusses such as AS-Interface orDeviceNet.Possible scope of functions:• <strong>Control</strong> of process valves- single-acting/double-acting- with external pneumatic control• Position feedback with maximum twoadjustable inductive limit switchesor two micro limit switches• Electrical control of the control head,optionally via multipole (parallel wiring)or field bus interface (AS-Interface orDeviceNet)• Relief valve for burst protection• ATEX II 2G EEx ia IIC T6For more information consult individual datasheets, downloadable at www.burkert.comSubject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!