21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

368Digital Timer unitwith 8 switch functions1078-2Type 1078-2 can be combined with...• Same as Type 1078-1, except:• Programmable using separateoperating unit• 8 different switching functions• Program changes only possible withoperating unit (protective function)• 2-button operation with displayType 5281/6213Solenoid valveType 0330/0331Solenoid valveType 0255/0256Solenoid valveType 6518/6519Solenoid valveType 6519Namur<strong>Control</strong>lersThe Type 1078-2 works on the basis of a microprocessorand is used for controlling the cycletimes of solenoid valves. 8 different cycle timescan be set up.The controller is plugged onto the tag connectorof the solenoid valve using the integrated instrumentsocket according to DIN EN 175301-803(previously DIN 43650) Form A and can also beconnected to a binary signal generator (Start andReset).The 1077-2 operating unit is used to set switchingcycles and interval periods using the 2 functionbuttons. Once these parameters have been set,the operating unit can be removed from the timerunit. The programmed values remain stored in theoperating unit and the controller.Technical dataOperating voltage12 - 24/24 - 48 V/DC, 24-48 V/50 - 60 Hz,110 - 230V/50 - 60 HzVoltage tolerance ±10%Nominal power1.5 WSwitching outputFor the control of solenoid valves etc.Switching voltageAs operating voltageSwitching currentat 12 - 24 V/DCMax. 2 Aat 24 - 48 V/50-60 Hz Max. 1.5 A (7,5 A)at 110 - 230 V/50-60 Hz Max. 0.5 A (2 A)Electrical connection 5-pin terminal strip in the body,PG9 cable connector, up to 1.5 mm 2 wires,Cable Ø 6 to 7 mm, can be turned through 90°Number of terminals 2 pins and protective conductorPlug connection Integrated cable plug to DIN EN 175301-803(previously DIN 43650) Form AProtection classIP 65 with valveClearance/leakage paths According to VDE 0100Operating temperature -10 to +60 °C (14 to 140 °F)Storage temperature -10 to +80 °C (14 to 176 °F)Operation With plug-on operating unit Type 1077-2Setting8 functions with 2 buttons on the operating unitType 1077-2 (not supplied as standard)Time0.2 s up to 9999 h, continuousTolerance 1%ResolutionRange up to 199 s10 msRange up to 199 min1 sRange up to 99 h1 minRange up to 9999 h1 hOptionsBinary inputs for external triggeringLED displayMains voltageSwitch statusDisplay4 1/2 digit(on operating unit Type 1077-2) 7-segment LCD displayInstallationAs requiredMountingWith cheesehead screwsBody materialPolyamideSubject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!