21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

288Electromagnetic flow transmitter8041Type 8041 can be combined with...• Sensor in solid-state technology(no moving parts)• Working as a transmitter and/or asan On/Off controller• Automatic calibration of full scale: TEACH-IN• Clean In Place (CIP)• FDA approvedType S020Insertion fittingType 8644-PAirlineValve islandType 2712 (8630)Continuous Top-<strong>Control</strong>Type 8025T/BUniversal flow transmitter /batch controllerremote versionPLCSensorsThe flowmeter Type 8041 is designed for pipes withdiameters ranging from DN 6 to DN 400 and liquidshaving a conductivity > 20 µS/cm.The transmitter is a magmeter made up of an electronicmodule and a stainless steel sensor.It is fitted with a 4-20 mA output, a pulse rate outputand a relay output.The different parameters can be programmed bymeans of five switches, a push-button and a ledbargraph.The Type 8041 can be used in applications withhigher pressure and higher temperature.Technical dataPipe diameter DN 6 to DN 400 (see fitting S020, pages 292 to 299)Measurement <strong>range</strong> from 0.02 m 3 /h up to 4500 m 3 /hFlow velocityAccuracy 1)TEACH-INStandard K-factorLinearityRepeatability 1)0.2 to 10 m/s(for measured value from 1 to 10m/s and -20 °C < T° < 130°C)≤ ±2 % o.R.*≤ ±4 % o.R.*±(1% o.R.*+ 0.1% o. F.S.*)≤ 0.25% o.R.*Electrical connection Cable glands M 20 x 1.5Voltage supply cable Shielded; cross section: max. 0.75 mm 2Protection classRelative humidityAltitude max. for operating 2000 m<strong>Fluid</strong> temperatureAmbient temperatureStorage temperatureMax. fluid pressureConductivityMaterialsHousing, coverWetted partsFittingFinger, electrodesSeal / Electrode holderOperating voltageOutputCurrentFrequencyRelayCurrent consumptionAlarmFull scale exceedingFault signallingUser parameters* o.F.S. = of Full Scaleo.R. = of ReadingIP 65 with cable gland mounted and tightenedmax. 80%, non condensated-20 to +150 °C (-4 to +302 °F) (depends on fitting)-10 to +60 °C (14 to 140 °F)-20 to +60 °C (-4 to 140 °F)Max. PN16 (depends on temperature and fitting material, seepressure-temperature chart, page 295)Min. 20 μS/cmPPA, glass fibre reinforcedPVC, PP, PVDF, stainless steel 1.4404/316L, brassStainless steel (DIN1.4404)EPDM (FDA agreements) / PEEK (FDA agreements)18-36 V DC (3 wires) - filtered and regulated; protectedagainst reverse of polarity4-20 mA, 100 ms refresh rate;max load: 1300 Ω at 36 V DC, 330 Ω at 18 V DC0-240 Hz, duty cycle = 50% ±1%, 100 mA max.,protected against short-circuits and polarity reversalsNormally open or normally closed (depending on wiring),250 V AC, 3 AMax. 220 mA22 mA and 256 Hz22 mA and 0 HzSaved in EEPROM1) under reference conditions, i.e. fluid = water, temperatures = 20°C,up and downstream distances respected, adapted dimensions and pipesSubject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!