291Dimensions [mm]Mounted on S020 fitting180H218181211131238880459188116see Type S020 Insertion fittingfor H dimensions on page 294.Interconnection possibilities<strong>Control</strong> valveSolenoid valvePLCPulseoutputRelayoutput4-20 mAoutputType 8045Electromagneticflow transmitterOrdering chart for the Type 8045 electromagnetic transmitterType S020Insertion fitting(see pages 292 to299)Voltage supplyOutputsRelaysSensor versionSensorsElectricalconnectionItem no.18-36 V DC 4-20 mA, pulse No short 2 cable glands 449 670long 2 cable glands 449 6722 short 2 cable glands 449 671long 2 cable glands 449 673* To select the sensor length, please consult the Note on fitting dimensions Type S020 (pages 295 to 297).Note regarding the ordering of a complete transmitter:A complete transmitter 8045 consists of the Insertion fitting Type S020 (see pages 292 to 299) and the transmitter Type 8045.1 set (1 stopper for not used cable gland M 20 x 1.5 + 1 multiway seal 2 x 6 mm for cable gland + 1 black EPDM seal for the sensor + 1 mounting instruction sheet) is supplied with eachtransmitter.Please order the relevant Insertion fitting and the transmitter separately!Attention!No liability will be accepted for design errors. Please contact our Bürkert engineers as early as possible in the planning phase.Subject to modifications