21.07.2015 Views

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

Fluid Control Systems Selected product range

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

282System versions – Panel-mounted or wall-mounted transmitter Type 8025 T8025 TSensorsThe panel-mounted version of theType 8025 flow transmitter consistsof an electronic module 8025 Tintegrated in a front-cover.The associated separate flow sensorsare Type 8020 (see p. 280-281), Type 8030 (see p. 258-259)“low power”, or another flow sensor available fromBürkert or, for the universal transmitter only, any othersensor from the market.The wall-mounted version of theType 8025 flow transmitter consistsof the electronic module 8025 T inan IP65 enclosure.The associated separate flow sensorsare Type 8020 (see p. 280-281), Type 8030 (see p. 258-259)“low power”, or another flow sensor available fromBürkert or for the universal transmitter only, any othersensor from the market.Technical dataElectrical connectionTerminals (panel-mounted version), terminals via cable glandsM 16 x 1.5 (wall-mounted version)Connection cable Shielded; cross section: max. 1.5 mm 2Protection classRelative humidityAmbient temperatureStorage temperatureMaterialsHousing, coverFront panel folioScrewsUniversal flow transmitterIP 65 (panel-mounted and wall-mounted versions)IP 20 (panel-mounted version, inside the cabinet)≤ 80%, non condensated0 to +60 °C (32 to 140 °F)0 to +60 °C (32 to 140 °F)PC (panel-mounted version), ABS (wall-mounted version)PolyesterStainless steelCompatibility Bürkert flow sensor with frequency output (8020, 8030,8030 HT, 8041, 8031, 8070, 8071) or other sensors withcompatible data.Operating voltagePanel-mounted versionWall-mounted versionCurrent consumptionwithout sensorSensor inputSensor outputVoltage supplyCurrent consumptionOutputSignal currentPulseRelay (option)Flow transmitter12 to 30 V DC - filtered and regulated12 to 30 V DC; 115/230 V AC - filtered and regulated≤ 100 mA with relay≤ 60 mA without relay0.5 Hz or 2.5 Hz up to 1400 HzOpen collector NPN (with 470 Ω or 2.2 kΩ resistance) or PNP,Coil, TTL, CMOS (with 100 kΩ resistance)13...30 V DC; +12 V AC or + 27 V AC(with a 115/230 V AC powered transmitter)Max. current available from transmitter:25 mA (version 115/230 V AC)100 mA (version 13-30 V DC)4-20 mA (3-wire with relays; 2-wire without relay),max. load: 1300 Ω at 30 V DC; 1000 Ω at 24 V DC;550 Ω at 15 V DC; 400 Ω at 13 V DC;1200 Ω at 115/230 V ACTransistor open collector, NPN/PNP, 0...30 V DC;100 mA, protected2 relays, programmable, 3A, 230 V ACCompatibility Bürkert flow sensor with frequency output 8020, 8030or 8070 (sinus or pulse low power version)Operating voltageCurrent consumptionwithout sensorSensor inputSensor outputVoltage supplyCurrent consumptionOutputCurrent signalPulseRelay12 to 30 V DC; 115/230 V AC - filtered and regulated≤ 70 mA with relay≤ 20 mA without relay2.5 Hz up to 300 HzSinus or Pulse low power (open collector NPN)12-30 V DC (Transmitter);Max. current available from transmitter: 1 mA4-20 mA (3-wire with realys; 2-wire without relay),max. load: 900 Ω at 30 V DC, 500 Ω at 24 V DC,100 Ω at 15 V DC, 800 Ω at 230 V ACTransistor open collector, NPN/PNP, 0... 30 V DC,100 mA, protected2 relays, 3A, 230 VAC, freely programmableSubject to modifications

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!