Chapter 4 ������������ ��� �������<br />
For performance and safety reasons, the system must always be connected to the<br />
ground. The ground must be connected prior to all the other connections.<br />
For performance and safety reasons, the whole system must always be coupled<br />
to the ground. The ground must be connected before any other connections.<br />
The ground protection connection terminal must always be connected to the<br />
ground. Protective grounding terminal shall be permanently connected to the ground.<br />
4.3.1.6 POWER UP<br />
Having made all the connections, it is now time to power up the system.<br />
- Insert the mains cable in the socket on the rear of the unit.<br />
- Press the ON/OFF button. The system will reinitialize (duration: 3 to 4 minutes).<br />
To stop the system:<br />
- Press the ON/OFF button, the RED LED will flash.<br />
- Wait until the LED stops flashing and is lit steadily (between 15 seconds and 3 minutes<br />
depending on the configuration): the system is switched off.<br />
4.3.1.6.1 Power up of Alcatel Reflexes terminals<br />
On powering up, Reflexes sets execute a self-test:<br />
- Display Test<br />
- Test of the LEDs or icons on the terminal and add-on module, if any<br />
- Audio test<br />
If this sequence is correct, the display on the Alcatel Reflexes terminals shows the system<br />
date: Monday 01 January 00h00.<br />
After powering up, you can activate the system from an Advanced Reflexes terminal or by<br />
OMC (refer to the specific notice).<br />
4.4 Reflexes and e-Reflexes Terminals<br />
4.4.1 Reflexes Terminals<br />
4.4.1.1 <strong>Installation</strong> procedure<br />
4.4.1.1.1 REMINDER: SYSTEM - Alcatel Reflexes TERMINAL SEPARATION<br />
- SYT type 0.5 mm cable: 800 m (terminal without option) or 600 m (terminal with S0 or Z<br />
option)<br />
- 278 type 1.6 mm cable: 1200 m (terminal without option) or 850 m (station with S0 or Z<br />
option)<br />
4.4.1.1.2 Premium AND Advanced Reflexes TERMINALS<br />
4-36 ������������ � ����� � ����� ���� � ������������ ������