Chapter 4 ������������ ��� �������<br />
The e-Reflexes terminals are connected to:<br />
1. A PC (optional). The PC is a workstation that uses the station's switch function (link<br />
through straight RJ45 cable). The connecting PC does not power; it does not exist on the<br />
Easy e-Reflexes terminal.<br />
RJ45 pin 1 2 3 4 5 6 7 8<br />
Outputs TXB+ TXB- RXB+ A1 A2 RXB- B1 B2<br />
2. The IP network (straight RJ45 cable).<br />
RJ45 pin 1 2 3 4 5 6 7 8<br />
Outputs RXA+ RXA- TXA+ TXA-<br />
4.4.2.2 Start-up<br />
3. The mains power socket for local power<br />
Pin 1 2<br />
Signal A 42 V- A 42 V+<br />
4.4.2.2.1 Configuration procedure<br />
Depending on the network topology, the configuring of the IP Enablers can be:<br />
- Completely automatic, if they are on the same subnet as Alcatel-Lucent OmniPCX Office<br />
Communication Server: simply connect the terminals to the LAN and connect the power<br />
supply unit. The DHCP server allocates the dynamic IP addresses and the TFTP server<br />
integrated into the CPU-1/CPU-2/CPU-3/CPUe-1/CPUe-2 board downloads the binary into<br />
the IP Enabler (integrated in the terminal).<br />
4-42 ������������ � ����� � ����� ���� � ������������ ������