Chapter 4 ������������ ��� �������<br />

The e-Reflexes terminals are connected to:<br />

1. A PC (optional). The PC is a workstation that uses the station's switch function (link<br />

through straight RJ45 cable). The connecting PC does not power; it does not exist on the<br />

Easy e-Reflexes terminal.<br />

RJ45 pin 1 2 3 4 5 6 7 8<br />

Outputs TXB+ TXB- RXB+ A1 A2 RXB- B1 B2<br />

2. The IP network (straight RJ45 cable).<br />

RJ45 pin 1 2 3 4 5 6 7 8<br />

Outputs RXA+ RXA- TXA+ TXA-<br />

4.4.2.2 Start-up<br />

3. The mains power socket for local power<br />

Pin 1 2<br />

Signal A 42 V- A 42 V+<br />

4.4.2.2.1 Configuration procedure<br />

Depending on the network topology, the configuring of the IP Enablers can be:<br />

- Completely automatic, if they are on the same subnet as Alcatel-Lucent OmniPCX Office<br />

Communication Server: simply connect the terminals to the LAN and connect the power<br />

supply unit. The DHCP server allocates the dynamic IP addresses and the TFTP server<br />

integrated into the CPU-1/CPU-2/CPU-3/CPUe-1/CPUe-2 board downloads the binary into<br />

the IP Enabler (integrated in the terminal).<br />

4-42 ������������ � ����� � ����� ���� � ������������ ������