Row Description<br />

Serial Number (Logical) A relocatable serial number assigned to the server blade<br />

UUID<br />

UUID (Logical)<br />

Server Name<br />

BIOS Asset Tag<br />

ROM Version<br />

Server NIC information<br />

The UUID assigned to the server blade<br />

A relocatable UUID assigned to the server blade<br />

If configured through the BIOS, this appears as the ProLiant server name. For ProLiant<br />

or Integrity server blades with <strong>HP</strong> OS agents installed, this is the server host name.<br />

If configured, this is the asset tag of the installed server blade.<br />

ROM version number<br />

Row Description<br />

Ethernet FlexNIC<br />

LOM:(x)-(a-d)<br />

Ethernet FlexNIC (NIC<br />

x) LOM: (y)-(a-d)<br />

Port: NIC x<br />

Port: iLO<br />

Port: iSCSI x<br />

Mezzanine card information<br />

Column Description<br />

Mezzanine Slot<br />

Mezzanine Device<br />

A Flex-10 enable 10Gb NIC configured in Virtual Connect. The four FlexNICs on port<br />

x of a server LOM that supports Flex-10 are numbered LOM:x-a, LOM:x-b, LOM:x-c,<br />

and LOM:x-d, where x is the port 1–4. See the <strong>HP</strong> Virtual Connect c-Class <strong>BladeSystem</strong><br />

<strong>User</strong> <strong>Guide</strong> for detailed information on configuring Flex-10 NICs.<br />

A Flex-10 enable 10Gb NIC configured in Virtual Connect, where x is a NIC 1–32.<br />

The four FlexNICs on port y of a server LOM that supports Flex-10 are numbered<br />

LOM:y-a, LOM:y-b, LOM:y-c, and LOM:y-d, where y is the port 1–8. See the <strong>HP</strong> Virtual<br />

Connect c-Class <strong>BladeSystem</strong> user guide for detailed information on configuring<br />

Flex-10 NICs.<br />

The MAC address of this NIC port, where x is a NIC port 1-4.<br />

The MAC address of the iLO port for the server blade in this enclosure slot<br />

The MAC address of this iSCSI port, where x is an iSCSI port 1–8.<br />

The physical slot in which the mezzanine card is located<br />

The common or product name of the mezzanine device<br />

Mezzanine Device Port The port assigned to the mezzanine device<br />

Device ID<br />

CPU and memory information<br />

Row Description<br />

The MAC address of the interconnect bay port<br />

CPU 1 through CPU (x) CPU type and speed or Not present<br />

Memory<br />

Memory size<br />

Configuring the <strong>HP</strong> <strong>BladeSystem</strong> c7000 enclosure and enclosure devices 143