Row Description<br />

Serial Number<br />

Diagnostic Information<br />

The unique serial number of the fan.<br />

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a<br />

failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.<br />

Row Description<br />

Device Identification<br />

Data<br />

Device Location<br />

Device Operational<br />

Device Degraded<br />

Fan Presence<br />

Device Mismatch<br />

Fan models<br />

Information such as model name, part number, serial number, and other information<br />

used to identify the device is checked. This data is also referred to as FRU data. If the<br />

data is not present or not readable by the <strong>Onboard</strong> <strong>Administrator</strong>, a device<br />

identification data error displays. Possible values are OK or Error.<br />

Incorrect fan location. Possible values are OK or Incorrect location for proper device<br />

cooling.<br />

Device has failed; status was not requested by the <strong>Onboard</strong> <strong>Administrator</strong>.<br />

Device has failed; status was requested by the <strong>Onboard</strong> <strong>Administrator</strong>.<br />

This field indicates whether a fan is required to support the current fan rule.<br />

This field indicates different fan models are installed in the same enclosure and you<br />

need to install the same fan models in each bay.<br />

The c3000 enclosure supports Active Cool 100 Fan and Active Cool 200 Fan models. The c7000 enclosure<br />

only supports the Active Cool 200 Fan model. You cannot mix fan models in the c3000 enclosure. If you mix<br />

fan models or you put the wrong fan model in the enclosure you see a Device Mismatch error in the<br />

Diagnostic Information table.<br />

To update the fan information, click Refresh.<br />

For proper installation of the fans into the enclosure, see the <strong>HP</strong> <strong>BladeSystem</strong> c7000 Enclosure Setup and<br />

Installation <strong>Guide</strong>.<br />

c7000 Enclosure fan location rules<br />

The <strong>HP</strong> <strong>BladeSystem</strong> c7000 Enclosure ships with four <strong>HP</strong> Active Cool fans and supports up to 10 fans. You<br />

must install fans in even-numbered groups, based on the total number of server blades installed in the<br />

enclosure, and install fan blanks in unused fan bays.<br />

Four Fan Rule<br />

Configuring the <strong>HP</strong> <strong>BladeSystem</strong> c7000 enclosure and enclosure devices 177