Connection Port Number Connects to interconnect bay/port<br />

Server A Mezzanine*<br />

Server B Embedded NIC<br />

Server B Mezzanine*<br />

Port 1<br />

Port 2<br />

NIC 1 (Port:1)<br />

NIC 2 (Port:2)<br />

Port 1<br />

Port 2<br />

AMC Telco I/O expansion blade<br />

5/Port N<br />

6/Port N<br />

2/Port<br />

4/Port N<br />

7/Port N<br />

8/Port N<br />

The table lists the available configurations for AMC Telco devices installed in device bay N (1-16).<br />

Connection Port Number Connects to interconnect bay/port<br />

AMC Embedded (1)<br />

AMC Embedded (2)<br />

Port 1<br />

Port 2<br />

Port 3<br />

Port 4<br />

Port 5<br />

Port 6<br />

Port 7<br />

Port 8<br />

<strong>HP</strong> ProLiant BL2x220c G7 Server<br />

1/Port N<br />

2/Port N<br />

3/Port N<br />

4/Port N<br />

5/Port N<br />

6/Port N<br />

7/Port N<br />

8/Port N<br />

The following table lists the available configurations for ProLiant BL2x220c G7 devices installed in c7000<br />

device bay N (1-8).<br />

Connection Port Number Connects to interconnect bay/port<br />

Server A Embedded NIC<br />

NIC 1 (Port:1)<br />

NIC 2 (Port:2)<br />

1/Port N<br />

3/Port N<br />

Server A NC543i* Port 1 5/Port N<br />

Server B Embedded NIC NIC 1 (Port:1)<br />

2/Port N<br />

NIC 2 (Port:2)<br />

4/Port N<br />

Server B NC543i* Port 1 7/Port N<br />

*The ProLiant BL2x220c G7 Server embedded NC543i is automatically configured by the <strong>Onboard</strong> <strong>Administrator</strong> to<br />

Ethernet, if Ethernet interconnect modules are installed in bays 5 and 6, or to IB if a double-wide IB interconnect is<br />

installed in bay 5. To change the NC543i configuration from one type to another, power off all the ProLiant BL2x220c<br />

G7 Servers, and replace the interconnect module with the other type. Reboot the active <strong>Onboard</strong> <strong>Administrator</strong> or reseat<br />

all the ProLiant BL2x220c G7 Servers and the <strong>Onboard</strong> <strong>Administrator</strong> reconfigures all the embedded NC543i for the<br />

new interconnect type.<br />

<strong>HP</strong> ProLiant BL680c G7 Server<br />

The following table lists the port mapping for the ProLiant BL680c G7 server blades installed in c7000 device<br />

bay N (2, 4, 6, or 8).<br />

Connection Port Number Connects to interconnect bay/port<br />

A-Side Embedded NIC<br />

B-Side Embedded NIC<br />

A-Side Mezzanine 1<br />

NIC 1<br />

NIC 2<br />

NIC 3<br />

NIC 4<br />

NIC 5<br />

NIC 6<br />

Port 1<br />

Port 2<br />

1/Port N+8<br />

2/Port N+8<br />

1/Port N<br />

2/Port N<br />

1/Port N+7<br />

2/Port N+7<br />

3/Port N<br />

4/Port N<br />

Port mapping 234