To view the enclosure Status screen, from the tree view, select Enclosure Information.<br />

Status overview<br />

Row Description<br />

Enclosure Status The overall status of the enclosure. Possible values are Unknown, OK, Degraded, and<br />

Failed.<br />

Active OA Status The overall status of the Active <strong>Onboard</strong> <strong>Administrator</strong>. Possible values are Unknown,<br />

OK, Degraded, and Failed.<br />

Standby OA Status The overall status of the Standby <strong>Onboard</strong> <strong>Administrator</strong>. Possible values are Absent,<br />

Unknown, OK, Degraded, and Failed.<br />

Enclosure Power Mode The power redundancy mode. Possible values are AC Redundant, Power Supply<br />

Redundant, Not Redundant, or Unknown. For information on these modes, see the <strong>HP</strong><br />

<strong>BladeSystem</strong> c7000 <strong>User</strong> <strong>Guide</strong>.<br />

Diagnostic Information<br />

Diagnostic information is gathered by polling a device microcontroller (resulting in a degraded status if a<br />

failure has occurred) or is sent by the device microcontroller, without being polled to report a failure.<br />

Row Description<br />

Device Identification<br />

Data<br />

Redundancy<br />

Contains information on model name, part number, serial number, and other<br />

information used to identify the device. This data is also referred to as FRU data. Device<br />

identification data error displays if the data is not present or not readable by the<br />

<strong>Onboard</strong> <strong>Administrator</strong>.<br />

Possible values are OK or Error. An error indicates the redundant <strong>Onboard</strong><br />

<strong>Administrator</strong>s are having problems syncing up. Check the syslog for errors. Possible<br />

reasons for the error are mismatched firmware or a software or hardware failure.<br />