Disabled—Disables powerdelay for this bay. <strong>HP</strong> <strong>BladeSystem</strong> <strong>Onboard</strong> <strong>Administrator</strong> grants power to this<br />

bay based on its power settings: for a device configured to auto power-on, the device is granted power<br />

following an enclosure power cycle after all the <strong>Onboard</strong> <strong>Administrator</strong> configuration checks are complete.<br />

Enabled—Enables powerdelay for this bay. <strong>HP</strong> <strong>BladeSystem</strong> <strong>Onboard</strong> <strong>Administrator</strong> turns on this bay based<br />

on the number of seconds elapsed following the detection of an enclosure power cycle event.<br />

No Poweron—Prevents component power on for the bays with this configuration until after the <strong>HP</strong><br />

<strong>BladeSystem</strong> <strong>Onboard</strong> <strong>Administrator</strong> logs PowerDelay has completed for the selected devices.<br />

At this time, if the device is configured to auto power-on, the device grants power following an enclosure<br />

power cycle after all the <strong>Onboard</strong> <strong>Administrator</strong> configuration checks are complete.<br />

If the device is configured to disable auto poweron, the device remains off following an enclosure power<br />

cycle independent of the setting of power delay for that bay.<br />

Device Bays Standard tab and Double Dense tabs<br />

The Device Bays Standard tab indicates the current settings for all the primary bays based on the type of<br />

enclosure. To change a setting on a particular device bay, use the menu under the Enabled column and select<br />

Enabled, Disabled or No Poweron. If Enabled is selected, a power delay in seconds must be entered in the<br />

Delay column for this bay. The minimum value is 1 second; the maximum value is 3600 seconds.<br />

If double dense servers are installed in an enclosure the power delay settings for Side A and Side B are<br />

controlled in the Double Dense Side A and Double Dense Side B tabs.<br />

Interconnect Bays tab<br />

Configuring the <strong>HP</strong> <strong>BladeSystem</strong> c7000 enclosure and enclosure devices 75