Parts and Accessories<br />

Table F-1. List of Consumables and Accessories (Continued)<br />

Description<br />

DAR Inspiratory Bacteria Filters<br />

Electrostatic Filter, Large (formerly Barrierbac)<br />

Electrostatic Filter, Small (formerly Barrierbac S)<br />

Electrostatic Filter; Small, Angled Port (formerly Barrierbac S Angled)<br />

Adult-Pediatric Electrostatic Filter HME, Large (formerly Hygrobac)<br />

Adult-Pediatric Electrostatic Filter HME, Small (formerly Hygrobac S)<br />

Adult-Pediatric Electrostatic Filter HME; Small, Angled Port (formerly Hygrobac S Angled)<br />

Infant-Pediatric Electrostatic Filter HME, Small (formerly Hygroboy)<br />

Adult-Pediatric Mechanical Filter HME, Large (formerly Hygroster)<br />

Adult-Pediatric Mechanical Filter HME, Compact (formerly Hygroster Mini)<br />

Mechanical Filter, Large (formerly Sterivent)<br />

Mechanical Filter, Compact (formerly Sterivent S)<br />

Mechanical Filter, Small (formerly Sterivent Mini)<br />

Adult-Pediatric HME (formerly Hygrolife II)<br />

Table F-2 provides a list of consumable parts available for the ventilator.<br />

Warning<br />

To ensure proper performance of the ventilator, use a patient circuit recommended by <strong>Covidien</strong><br />

in this manual; refer to chapter 4, “Installation and Assembly” and Appendix F, “Parts and<br />

Accessories”. The total specified length of the patient circuit tubing as measured from the<br />

ventilator outlet to the ventilator inlet is 1.1 metres (3.6 ft) to 2.0 metres (6.6 feet). The tubing<br />

must conform to all applicable standards and must be fitted with Ø 22 mm terminals that also<br />

conform to all applicable standards. Ensure that both the length and the internal volume of the<br />

patient circuit are appropriate for the tidal volume: a corrugated tube of Ø 22 mm for adult<br />

patients, and a corrugated tube of Ø 15 mm for pediatric patients with a tidal volume lower<br />

than 200 ml.<br />

Table F-2. List of Circuits<br />

Description Part Number<br />

DAR Double limb patient circuit with exhalation valve, 5094000<br />

180 cm, PVC, ADULT<br />

DAR Double limb patient circuit with exhalation valve, 5093900<br />

180 cm, PVC, PEDIATRIC<br />

DAR Single limb patient circuit with exhalation valve, 5093600<br />

180 cm, PVC, ADULT<br />

DAR Single limb patient circuit with exhalation valve, 5093500<br />

180 cm, PVC, PEDIATRIC<br />

DAR Single limb patient circuit without exhalation 5093300<br />

valve, 180 cm, PVC, ADULT<br />

DAR Single limb patient circuit without exhalation 5093100<br />

valve, 180 cm, PVC, PEDIATRIC<br />

For more information regarding parts and accessories for the Device name contact your service representative<br />

or www.covidien.com.<br />