Glossary<br />

Rtot<br />

Parameter measured by the ventilator equal to the total number of breaths per minute (bpm).<br />

Sensitivity<br />

This adjustable parameter determines the amount of inspiratory effort required by the patient<br />

before the ventilator delivers an assisted breath, or demands flow in the case of a spontaneous<br />

breath.<br />

The <strong>Puritan</strong> <strong>Bennett</strong> <strong>560</strong> <strong>Ventilator</strong> is flow-triggered, with sensitivity levels in the range from<br />

1 to 5: the lower the number, the more sensitive the trigger.<br />

Sigh<br />

A sigh is an increased volume of gas delivered to the patient at a set rate. i.e. every 50 breaths.<br />

Spont Cyc (Spontaneous Cycling)<br />

This is the percentage of ventilation cycles initiated by the patient over the previous 24 hour period.<br />

Spontaneous<br />

A ventilation mode that delivers assisted breaths only. Spontaneous mode does not provide breaths<br />

if the patient does not make an inspiratory effort greater than the sensitivity settings and there is<br />

no apnea backup rate.<br />

Standby<br />

The operational mode of the ventilator where it is powered (power supply I/O button set to the<br />

I position), but is not ventilating the patient.<br />

SIMV (Synchronised Intermittent Mandatory Ventilation)<br />

A ventilator mode which provides a mechanism for synchronising the ventilator-delivered breaths<br />

with a patient's inspiration, as detected by the ventilator.<br />

Tidal volume (Vt)<br />

Volume of gas delivered to the patient in a breath.<br />

Unfreeze<br />

Resumption of the waveform plot tracing on the ventilator’s display.<br />

V A/C (Volume Assist / Control)<br />

A ventilator mode which provides machine-initiated breaths are delivered at a clinician-set volume<br />

inspiratory time, and rate.<br />

Vent Time (Ventilation Time)<br />

The ventilation duration data is based on the patient counter and shows the total ventilation time<br />

in hours and minutes over the previous 24 hour period.<br />

Volume breath<br />

Inspiration of the selected volume, delivered over the selected inspiratory time.<br />

G-6 User’s <strong>Manual</strong>