Target temperature<br />
The minimum temperature of domestic hot water If the target temperature in the upper layer of the<br />
tank is not reached, the → auxiliary heating is switched on.<br />
Target value Targ<br />
Temperature T (°C)<br />
The temperature is a material property and describes the ability of a body to generate internal energy<br />
in the form of heat.<br />
Thermal buffer store<br />
Contains heating water for heat storage.<br />
Thermal conductivity λ [W/(mK)]<br />
The thermal conductivity states the amount of heat passing through one square meter of a 1m-thick<br />
layer of building material in an hour when the temperature difference between the two surfaces is 1<br />
Kelvin.<br />
Criterion for assessing the quality of insulating material.<br />
Thermal engineering<br />
Thermal engineering describes all aspects of energy conversion, storage, and transfer in machines<br />
and apparatus with the exception of electrical energy.<br />
Thermal equivalent<br />
Conversion process making energy sources comparable by their heat content (heating value).<br />
Thermosyphon system<br />
Operation in a closed circuit according to the gravity filtration principle without the use of pumps or<br />
controls.<br />
Tilt angle β (°)<br />
(inclination) Describes the angle between the horizontal and the collector surface. This is 0° when<br />
the collectors are flat on the ground and 90° when they are vertical.<br />
VDE<br />
Association for Electrical, Electronic & Information Technologies<br />
Volumetric flow rate Vp Flow [l/h] [l/m²h]<br />
The movement of a volume of a medium in a unit of time through the cross-section of a tube. The<br />
volumetric flow rate for the collector array is stated in l/h and can be specified either absolutely or<br />
relative to the collector area.<br />
Zero-loss collector efficiency η0<br />
States the proportion of radiated energy absorbed by the collector on vertical incidence when the<br />
median temperature of the heat transfer medium in the collector is equal to the ambient air<br />
temperature.<br />