7 System Definition User <strong>Manual</strong> <strong>T*SOL</strong><br />
2. You can change the percentage split between the heating loops.<br />
0% means, this loop is removed from the system.<br />
3. Choose between:<br />
percentage split supply between high- and low-temperature heating loops,<br />
or you can also determine up to what percentage of the daily maximum only the low-temperature<br />
loop supplies base load.<br />
7.7 External Heat Exchanger<br />
System Definition > External Heat Exchanger or system schematic<br />
Image: Input dialog for the external<br />
heat exchanger<br />
The quality of heat exchange can be defined in this dialog. Either the kA value or a specific value of the<br />
mean logarithmic temperature difference, from which the kA value can then be calculated, is entered. A<br />
suitable value for maximum output is hereby calculated from the system parameters.<br />
If you enter a kA value, this value is used for the simulation without conversion. The logarithmic<br />
temperature difference is accordingly displayed, but has no further influence on the simulation.<br />
In external heat exchangers for connection to a collector array, this value is calculated from 500 W/m²<br />
collector surface area.<br />
In external heat exchangers for connection of the buffer tank discharge to the DHW supply,<br />
Pmax is calculated from the pump flow rates and the maximum possible temperature difference.<br />
In heat exchangers for auxiliary heating of a swimming pool, Pmax is calculated by the power which<br />
would be required to heat the swimming pool from the cold water temperature to the target swimming<br />
pool temperature within 12 hours.<br />
7.8 Anti-Legionnaire's Switch<br />
System Definition > DHW Supply<br />
Image: Input dialog for Legionnaire's<br />
switch<br />