User <strong>Manual</strong> <strong>T*SOL</strong> 13 Appendix<br />

Controller<br />

The controller has the responsibility of ensuring optimal operation of the system. Control<br />

parameters can be set for various components. For storage tanks, for example, target temperatures,<br />

switching temperatures.<br />

Cooled Cooled<br />

Costs<br />

Consumption of goods to create and sell services and other goods.<br />

Daily consumption [l]<br />

The average daily domestic hot water consumption. This is usually 35-45 liters per person and day at<br />

a water temperature of 50°.<br />

Declared value for thermal conductivity λ [W/(mK)]<br />

Value of the → thermal conductivity of a construction material or product under specific external and<br />

internal conditions which can be considered typical of the behavior of this product when installed in<br />

a component.<br />

Default data Def.<br />

Design temperature °C<br />

Temperature determined by the relevant climate zone as per DIN EN 12831 supplement 1 table 1a. The<br />

design temperature is the maximum (necessary) temperature of the heating water which suffices at<br />

the lowest winter temperature for the heating system to provide the building with required amounts<br />

of heat.<br />

Deverter / injection system<br />

Special version of a control circuit. Particularly useful when the user is far away from the output but if<br />

required needs hot water promptly (often RLT)<br />

DHW consumption DHW con<br />

DHW requirement<br />

→ Daily consumption<br />

DHW requirement, specific, qT<br />

The heat, based on the floor space, that must be provided for heating domestic hot water. The<br />

guideline value from the EnEV is 12.50 kWh/m²a.<br />

Diffuse radiation Gdiff [W/m²]<br />

Part of solar irradiation which strikes a horizontal or tilted surface via scattering through air<br />

molecules and mist particles or reflection on clouds.<br />

DIN V 18599<br />

"Energy efficiency of buildings, calculation of net, final, and primary energy requirements for<br />

heating, cooling, ventilation, domestic hot water, and lighting" Basis of calculation for the EnEV<br />

2009 certifications for residential and non-residential buildings<br />

Direct radiation Gdir [W/m²]<br />

Part of solar irradiation which strikes a horizontal or tilted surface without changing direction.<br />