7 System Definition User <strong>Manual</strong> <strong>T*SOL</strong><br />
7.4.2.5 Buffer tank with external heat exchanger<br />
System Definition > Tank > Lower Collector Loading o or > Cont. Auxiliary Heating or > Flow<br />
Systems A18, B18, A17, B17 contain buffer tanks<br />
Image: Input dialog for buffer tank with<br />
external heat exchanger, Auxiliary Heating<br />
Control page<br />
The buffer tanks with direct loading and unloading can take varying forms depending on the system<br />
schematic selected.<br />
On the separate pages, the inlets and outlets of the different piping pairs for loading and unloading the<br />
tank as well as the respective specific losses of the piping inlets and the installation height of the<br />
temperature sensors are displayed but cannot be modified.<br />
On the Lower Collector Loading (buffer tank with auxiliary heating) or Upper Collector Loading (buffer<br />
tank without auxiliary heating) pages, only the maximum tank temperature may be entered.<br />
No changes can be made on the Dual Coil Auxiliary Heating page.<br />
On the Cont. Auxiliary Heating page, the desired tank temperature for the auxiliary heating is defined<br />
and entered in relation to the desired tank temperature for the switch-on / switch-off temperatures of<br />
the boiler.<br />
If you activate the Fixed field, you can predetermine the target temperature in the buffer tank. On<br />
activating the Accept field, the buffer tank target temperature, depending on operating state and<br />
requirements, is either the temperature required to load the water heater or for supplying the heating<br />
loop.<br />
In the limited operating times field, the auxiliary heating of the tank can be cut off for specific times of<br />
the day.<br />
The Flow page specifies the connections for unloading the tank.<br />
page 67 / 104 Dr. <strong>Valentin</strong> Energie<strong>Software</strong> GmbH