05.06.2013 Views

Manual T*SOL basic 5.0 - Valentin Software

Manual T*SOL basic 5.0 - Valentin Software

Manual T*SOL basic 5.0 - Valentin Software

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7 System Definition User <strong>Manual</strong> <strong>T*SOL</strong><br />

7.4.2.5 Buffer tank with external heat exchanger<br />

System Definition > Tank > Lower Collector Loading o or > Cont. Auxiliary Heating or > Flow<br />

Systems A18, B18, A17, B17 contain buffer tanks<br />

Image: Input dialog for buffer tank with<br />

external heat exchanger, Auxiliary Heating<br />

Control page<br />

The buffer tanks with direct loading and unloading can take varying forms depending on the system<br />

schematic selected.<br />

On the separate pages, the inlets and outlets of the different piping pairs for loading and unloading the<br />

tank as well as the respective specific losses of the piping inlets and the installation height of the<br />

temperature sensors are displayed but cannot be modified.<br />

On the Lower Collector Loading (buffer tank with auxiliary heating) or Upper Collector Loading (buffer<br />

tank without auxiliary heating) pages, only the maximum tank temperature may be entered.<br />

No changes can be made on the Dual Coil Auxiliary Heating page.<br />

On the Cont. Auxiliary Heating page, the desired tank temperature for the auxiliary heating is defined<br />

and entered in relation to the desired tank temperature for the switch-on / switch-off temperatures of<br />

the boiler.<br />

If you activate the Fixed field, you can predetermine the target temperature in the buffer tank. On<br />

activating the Accept field, the buffer tank target temperature, depending on operating state and<br />

requirements, is either the temperature required to load the water heater or for supplying the heating<br />

loop.<br />

In the limited operating times field, the auxiliary heating of the tank can be cut off for specific times of<br />

the day.<br />

The Flow page specifies the connections for unloading the tank.<br />

page 67 / 104 Dr. <strong>Valentin</strong> Energie<strong>Software</strong> GmbH

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!