Loan interest<br />
The amount of interest that has to be paid on a loan. If the loan interest rate is lower than the capital<br />
interest rate, borrowing a loan results in income from interest.<br />
Local heating LH<br />
Local heating describes the transfer of heat between buildings over relatively short distances in<br />
comparison with district heating.<br />
Low temperature circuit<br />
Heating loop with low flow and return temperature, e.g. for use with underfloor heating<br />
MeteoSyn<br />
Program for generating climate data.<br />
Nominal size [-] [mm]<br />
States the diameter of a pipe. DIN nominal piping sizes are used to calculate the collector loop piping<br />
widths. The term DN (diameter nominal) states the internal diameter. With copper piping, the outer<br />
diameter and the wall thickness of the material are stated.<br />
Off off<br />
Switch in a program dialogue box.<br />
On on<br />
Switch in a program dialogue box.<br />
Operating costs [€/a]<br />
Costs arising from operation of the system, e.g. maintenance costs, electricity costs. The → cash<br />
value and the → annuity of the operating costs are derived from the → capital interest, → rate of<br />
price increase, and the → lifetime.<br />
Operating period (h)<br />
Each respective component is active during the operating period. A component is not active during<br />
the specific time periods (hours, days or months) that have been switched off.<br />
Orientation angle α (°)<br />
(azimuth) Describes the angle of deviation of the collector area from the south in the northern<br />
hemisphere. It is 0° when the surface is facing due south. The azimuth is positive when facing west<br />
and negative when facing east. An orientation due west corresponds to a value of +90° and an<br />
orientation due east is -90°.<br />
Pay-back time<br />
Period of time required until the total of returns on an investment (static payback method) or its →<br />
capital value (dynamic payback method) reaches the amount of the investment. Here: the period of<br />
time the system must operate for the investment to yield a capital value of zero. The program does<br />
not calculate pay-back times of over 30 year.<br />
Primary Pr<br />
Primary energy requirement Qp [kWh/a] [kWh/(m²a)]<br />
Calculated amount of energy required for space heating and domestic hot water, which, in addition<br />
to energy content of the required fuel and the auxiliary power for the system technology, also<br />
includes amount of energy resulting from upstream process chains outside the building in extracting,<br />
converting, and distributing the respectively used fuels. - available in table form.<br />