7 System Definition User <strong>Manual</strong> <strong>T*SOL</strong><br />

• Photo Plan - Advanced functionality: http://valentintutorials.s3.amazonaws.com/PhotoPlanTutorials/EN/PhotoPlan_EN_2/PhotoPlanEN2.html<br />

7.3.5 Piping<br />

System Definition > Collector Array > Piping<br />

The following information is entered on the Piping page:<br />

Image: Dialog for the piping of the<br />

collector array<br />

The single length of piping and the thermal conductivity coefficient for insulation is subdivided and<br />

entered for inside, outside, and between the collectors. The distinction influences the calculation of<br />

piping losses.<br />

The nominal diameter of the pipes in the solar loop can be directly entered or calculated.<br />

If you select specific, the program calculates the pipe diameter after you have entered the flow velocity.<br />

As the calculation results in inexact values, the program automatically selects the next large DIN nominal<br />

pipe diameter. <strong>Manual</strong> changes are possible at any time.<br />

The thickness of insulation can be entered exactly or as % of nominal diameter. In this case, the<br />

following insulation thicknesses are available: 20mm, 30mm, 40mm, 50mm, 65mm, 80mm, and 100mm.<br />

For values up to 80mm, the thickness of the insulation is set to the next higher nominal diameter, while a<br />

nominal diameter of 100mm is calculated for values above 80mm. The specific setting of 100% is<br />

recommended, i.e. the thickness of the insulation approximates the nominal diameter.<br />

7.4 Tanks<br />

System Definition > Tank or system schematic<br />

Different types of tanks are loaded depending on the system. The following tank types are included:<br />

• Single coil DHW tank<br />

• Dual coil DHW tank<br />

• Heating buffer tank<br />

• Combination tank (internal heat exchanger or tank in tank)<br />