User <strong>Manual</strong> <strong>T*SOL</strong> 13 Appendix<br />
Annual heating requirement, specific, qh [kWh]<br />
The heat, based on the floor space, that must be yielded within a year to maintain a target<br />
temperature in the building (effective energy).<br />
Annuity A<br />
A series of equal payments, allowing for → lifetime and interest rate, for repayment of a capital debt.<br />
It is the product of annuity factor and investment sum.<br />
Anti-Legionnaire's switch LEG<br />
The guidelines of the German Association for Gas and Water specify that the entire content of the<br />
storage tanks and the piping in systems with a drinking water storage tank size of 400 liters and<br />
domestic hot water pipe content of over 3 liters must be heated to 60° once a day. The hot water<br />
storage tank is loaded in adjustable intervals in systems with an anti-Legionnaire's switch.<br />
Annual energy requirement<br />
-> Final energy requirement<br />
Aperture Aa (m 2 )<br />
Largest projected area through which unconcentrated solar irradiation enters the collector. In flat<br />
plate collectors, the area of the collector covering through which solar irradiation can penetrate the<br />
inside of the collector housing (light penetration area). In evacuated tube collectors, the aperture is<br />
the product of the length and width of the absorber strip and the number of tubes. If evacuated tube<br />
collectors are fitted with a reflector (→ CPC), the aperture is equal to the product of the length and<br />
width of the mirror surface<br />
Auxiliary heating AuxH<br />
Ensures that the → target temperature is reached even when there is insufficient irradiation. Where<br />
applicable, it also supplies the heating loop. Usually refers to the boiler.<br />
A/V ratio<br />
The A/V ration is the quotient of area to volume and is displayed in the unit 1/m.<br />
Balance (B)<br />
→ Energy balance<br />
Balancing<br />
→ Energy balance<br />
Base load [W, kW]<br />
Minimum load / output an energy supply system must make available constantly during a period of<br />
use.<br />
Boiler Boil<br />
Serves to convert chemical energy into heat.<br />
Boiler efficiency η [-]<br />
The boiler efficiency describes the relationship between the energy used by the boiler and the energy<br />
produced over a specific period of time.<br />
Buffer tank Buff<br />
A storage tank filled with domestic hot water, usually in steel. The heat is transferred either<br />
internally via a serpentine pipe or outside the tank by means of an external heat transfer medium.<br />
Building energy requirement Qb [kWh/a]<br />
Generic term for heating requirements, cooling requirements, energy requirements for hot drinking<br />
water, lighting, humidification.<br />
Dr. <strong>Valentin</strong> Energie<strong>Software</strong> GmbH page 90 / 104