User <strong>Manual</strong> <strong>T*SOL</strong> 7 System Definition<br />
7.4.2.6 DHW tank with external heat exchanger<br />
System Definition > Tank > DHW or system schematic<br />
Image: Input dialog for DHW tank with internal<br />
heat exchanger, DHW page<br />
The DHW standby tank and preheating tank with direct loading and unloading can take varying forms<br />
depending on the system schematic selected.<br />
These tanks only differ from buffer tanks in the additional DHW page, on which a cold water mixing<br />
valve at the tank outlet can be set in addition to the display of connection heights and connection losses.<br />
7.5 Auxiliary Heating<br />
System Definition > Gas Boiler > Parameters or system schematic<br />
Image: Input dialog for auxiliary heating<br />
The auxiliary heating ensures that the target tank temperature set in the tank dialog is maintained when<br />
solar irradiation is insufficient and, in systems with space heating, also supplies the heating loops.<br />
Ł Proceed as follows:<br />
1. Open the auxiliary heating by clicking Select.<br />
Dr. <strong>Valentin</strong> Energie<strong>Software</strong> GmbH page 68 / 104