User <strong>Manual</strong> <strong>T*SOL</strong> 5 Site Data<br />
Example: circulation loss = 2 * [single length of piping system] m * [spec. losses] W/m * ([DHW target<br />
temperature] °C- 20 °C)*[operating hours] h. Circulation losses may change following the simulation, as<br />
they are then calculated with the temperature at the tank outlet.<br />
The circulation operating times are set by clicking the fields in the clock (green area = in operation).<br />
They can be set the same for all days of the week or defined separately for each day. The annual<br />
circulation losses are displayed.<br />
5.3.3 Operating Times<br />
Symbol Hot water consumption > Operating Times<br />
On the Operating Timespage, you can define the days of the year on which domestic hot water is<br />
consumed. Entire months can be switched on or off by clicking on the monthly bars, separate days by<br />
clicking the magnifier (green area = in operation).<br />
At the same time, the total consumption for the operating time and the resulting energy requirement are<br />
displayed. The latter depends on the temperatures you enter in the box below.<br />
5.3.4 Deactivate Hot Water Consumption<br />
Symbol Hot water consumption<br />
If you want to deactivate hot water consumption , adopt the following settings:<br />
• Dialog Hot Water Consumption > Parameter:<br />
switch off circulation<br />
desired temperature = 20 °C<br />
cold water temperature = 20 °C<br />
• Dialog Hot Water Consumption > Control:<br />
maximum temperature limit for collector loop = 20 °C<br />
set target tank tamperature relative to DHW target temperature<br />
Entering a consumption of 0 liters is not permitted and would in any case not prevent loading by the<br />
collector array and the boiler.<br />
Dr. <strong>Valentin</strong> Energie<strong>Software</strong> GmbH page 26 / 104