User <strong>Manual</strong> <strong>T*SOL</strong> 7 System Definition<br />
In the Collector Loop Connection section, the position of the measurement sensors for switching on and<br />
off the collector loop and the maximum temperature limit of the tank are displayed. The maximum<br />
temperature limit can be changed.<br />
In the Redirection Valve section, the temperature difference for switching the three-way valve in the<br />
heating return is defined. If the total of tank temperature in the boiler return and input temperature is<br />
higher than the temperature in the heating return, the heating return is redirected in the tank, which is<br />
therefore unloaded.<br />
7.4.2.4 Heating buffer tank<br />
System Definition > Tank > Control or system schematic<br />
Image: Input dialog for heating buffer<br />
tank, Control page<br />
On the Control page, the single coil heating buffer tanks have the same input parameters as the single<br />
coil DHW tanks with the sole addition of an input field for defining the switching temperature of the<br />
three-way valve in the Redirection Valvesection. Here, the temperature difference for switching the threeway<br />
valve in the heating return is defined. If the total of upper tank temperature in the boiler return and<br />
input temperature is higher than the temperature in the heating return, the heating return is redirected in<br />
the tank, which is therefore unloaded.<br />