always come in pairs. All commands enclosed between BeginLoop and EndLoop are<br />

executed in a cycle.<br />

The command BeginLoop has one text parameter “LoopFile”, which contains the name<br />

(with a path, if necessary) of the so-called loop file. The loop file instructs RefFIT on how <strong>to</strong><br />

run the cycle. It is a text file, which has the same number of lines, as the desired number of<br />

cycle steps. Each line contains one or more words separated by space. The first word is the first<br />

cycle variable, the second word is the second variable and so forth.<br />

The cycle variables are used <strong>to</strong> modify text parameters of the commands in the cycle. If a<br />

text parameter contains combination “%1”, then it will be substituted by the first cycle variable.<br />

The combination “%2” is substituted by the second cycle variable etc. For instance, if the first<br />

cycle variable is “250”, then text string “C:\MYDATA\REFL_T%1.DAT” will become<br />

“C:\MYDATA\REFL_T250.DAT”. Such a substitution, for example, in the File parameter of<br />

the LoadDataset command will cause the loading of a different dataset on each cycle step.<br />