2.2.2.1 Station Type<br />
Station type will never be changed for a specific station. The option is only<br />
available if the administrator <strong>user</strong> ID is entered within the environment. So, if<br />
the <strong>machine</strong>’s actual stations change contact applications support to have this<br />
change made as well.<br />
2.2.2.2 Keys<br />
Displays physical keys of the station. Each station size has set keys within<br />
them. Keys for station will not be changed within NC Express unless<br />
physically changed on the <strong>machine</strong>.<br />
2.2.2.3 Load Angle<br />
Changing the load angle for a tool allows the tool to be used at different<br />
rotations (ex. 0°, 45° or 90°). Keys set for a specific tool within the tool library<br />
in conjunction with the keys in the turret station determine which load angles<br />
are listed in the Load Angle drop down.<br />
Remember- Keys set for tools need to be the same as how the physical tool is<br />
or can be keyed at the <strong>machine</strong>.<br />
2.2.2.4 Die Clearance<br />
Setting the die clearance for a tool loaded in the turret will set the die clearance<br />
for that tool when the turret is used. In the case that the tool has multiple die<br />
clearance set in the Tool library then NC Express will automatically set the die<br />
clearance that is needed for that tool. If multiple tools reside within the turret<br />
and have different die clearances set for them then NC Express will choose the<br />
correct die needed and use that station.<br />
2.2.2.5 Open Station<br />
Clears current tool loaded in the station and opens the station. Removes tool<br />
from station.<br />
2-21