Development <strong>of</strong> Atchchuvali Industrial Estate<br />

Jaffna District, Sri Lanka - Phase 01<br />

<strong>Tender</strong> Issue<br />

Bill No. 07: Sewer Disposal System<br />

Page B7 / 5<br />

Item No. Description Qty. Unit<br />

7P2.3 Fittings for 110mm diameter pipe 2 nr<br />

7P2.4 160mm diameter 845 m<br />

Rate<br />

LKR<br />

Amount<br />

LKR<br />

7P2.5 Fittings for 160mm diameter pipe 12 nr<br />

7P2.6 225mm diameter 137 m<br />

7P2.7 225mm diameter pipe upto pond / drain as per<br />

detail (Provisional quantity ) 10 m<br />

7P2.8 Fittings for 225mm diameter pipe (Provisional<br />

quantity ) 10 nr<br />

7P3<br />

BUILDER'S WORK<br />

Precast concrete Manhole type MH, <strong>of</strong> size<br />

1000mm diameter (internally), including precast<br />

concrete rings, MS rungs encapsulated with<br />

EPDM and fixed to wall at 300mm centres, inlet<br />

and outlet connections as per detail, to complete<br />

the manhole in working order.<br />

7P3.1 Depth exceeding 1.5m but not exceeding 2.0m 4 nr<br />

Precast concrete Drop Manhole type MH, <strong>of</strong><br />

size 1000mm diameter (internally), including<br />

precast concrete rings, MS rungs encapsulated<br />

with EPDM and fixed to wall at 300mm centres,<br />

inlet and outlet connections with drop<br />

arrangement, as per detail, to complete the<br />

manhole in working order.<br />

7P3.2 Depth exceeding 2.0m but not exceeding 2.5m 3 nr<br />

7P3.3 Depth exceeding 2.5m but not exceeding 3.0m 3 nr<br />

7P3.4 Depth exceeding 3.0m but not exceeding 3.5m 5 nr<br />

7P3.5 Depth exceeding 3.5m but not exceeding 4.0m 3 nr<br />

7P3.6 Depth exceeding 4.0m but not exceeding 4.5m 1 nr<br />

7P3.7 Depth exceeding 4.5m but not exceeding 5.0m 2 nr<br />

7P3.8 Inspection Chamber IC, size 600x600x300mm<br />

deep (internally), including cover, haunching and<br />

benching inside the chamber, inlet and outlet<br />

connections and finishing internal wall faces, all<br />

as per detail drawings and to complete the<br />

chamber in working order.<br />

8 nr<br />

7P3.9 Interceptor Manhole type IM, size<br />

600x600x1500mm deep (internally), including<br />

cover, haunching and benching inside the<br />

chamber, pipe support blocks, inlet and outlet<br />

connections and finishing internal wall faces, all<br />

as per detail drawings and to complete the<br />

manhole in working order. 22 nr<br />

Page Total Carried to Collection<br />

LKR<br />

Package 4: Waste and Sewer Disposal System<br />

Sewer Pipe Network