Tags and the Project Database<br />

you can convert PanelView program (developed with PanelBuilder32 ) into the IWS format and run them<br />

under any platform supported by IWS.<br />

• Import Screens: Check this option to import the graphical screens (including their objects and animations) to<br />

IWS.<br />

• Import Comm. Configuration: Check this option to import the communication interface (tags linked to PLC<br />

addresses) to IWS.<br />

• Report File: Press the Browse button to select the name of the text file exported from PanelBuilder32 (report<br />

printed to a text file).<br />

• ControlLogix Only: When importing a program that was configured to exchange data with ControlLogix PLCs,<br />

IWS can convert the communication interface to Ethernet/IP (ABCIP driver). To do so, type the IP Address<br />

of the PLC and its slot number. This information will be used to create the communication interface for the<br />

imported program. If the original program was already configured to use the Ethernet/IP interface, these<br />

fields can be left blank, because the IP Address and CPU Slot Number are retrieved from the program file<br />

itself.<br />

In the grid displayed in Step 3 for this Data Source Type, there is an additional field with the label Address,<br />

which displays the tag addresses from the PanelBuilder project.<br />

Tip: Please consult the documentation for this import wizard for detailed information about how<br />

to export an program from the *.PBA format to the text (*.TXT) format, using PanelBuilder32 , and<br />

import it into IWS.<br />

Note: See Steps 1, 2 and 3 of Import Wizard for the settings and fields that are common for all Source<br />

Types.<br />

Note: IWS does not support some special characters (e.g., [ ] . –) in tag names. When you import<br />

your PaneBuilder database into IWS, these special characters will be converted into underscores<br />

( _ ).<br />

IMPORTING FROM RSLOGIX 5000 CSV DATABASES<br />

This wizard allows you to import tags from a program for ControlLogix/FlexiLogix PLC developed with<br />

RSLogix 5000 and exported to a CSV file. When you import tags from the RSLogix 5000 CSV file, the<br />

Page 146<br />

<strong>InduSoft</strong> Web Studio