Alarms, Events, and Trends<br />

Field Remarks Syntax<br />

History > Generate Ack Messages<br />

History > Generate Norm Messages<br />

Colors in Alarm Controls > Enable<br />

Colors in Alarm Controls > FG and BG<br />

When checked, the alarm messages are stored in the history log when they are<br />

acknowledged.<br />

When checked, the alarm messages are stored in the history log when they become<br />

normalized.<br />

When checked, the alarms configured in this group will be displayed with the colors<br />

assigned to each alarm state (Activation, Acknowledgement or Normalization),<br />

according to the colors configured in the Alarm Group.<br />

You can configure the text foreground color (FG) and background color (BG) for<br />

the alarms displayed on the Alarms/Events Control object. Each alarm state can be<br />

displayed with a different color schema:<br />

• Activation: Alarm active and not acknowledged<br />

• Acknowledgement: Alarm active and acknowledged<br />

• Normalization: Alarm no longer active and not acknowledged.<br />

Checkbox<br />

Checkbox<br />

Color<br />

Color<br />

EMAIL SETTINGS FOR ALARM WORKSHEET<br />

IWS has the ability to send emails automatically when alarm events occur. The emails are sent using the<br />

standard SMTP (Simple Message Transfer Protocol). Therefore, you just need a valid email account with a<br />

SMTP Server and POP3 server — it is not necessary to install any additional software, such as Microsoft<br />

Outlook.<br />

Important: Before being email to send emails, it is necessary to execute successfully the CnfEmail<br />

function (from the built-in language) at least once. This function sets the email account parameters<br />

used when sending emails from the project (e.g., SMTP server, user name, password, and so forth).<br />

Alarms Worksheet — Email Settings<br />

Field Remarks Syntax<br />

Enable send automatic email Name of the tag associated with the alarm. Checkbox<br />

To, Cc, Bcc<br />

Subject<br />

Send 1 message per email<br />

Remove failed messages from the buffer<br />

Target addresses to whom the emails will be sent. You can configure multiple email<br />

addresses in each box (To, Cc and/or Bcc) by separating the addresses with the semicolon<br />

character ( ; ).<br />

When selecting "Use alarm message", the alarm message itself is used as the subject<br />

of the email to be sent. When selecting "Custom", you can configure a custom text to<br />

be used as Subject when sending the alarm.<br />

When checking this option, each alarm is sent in an individual email and all emails<br />

are sent when the Send Trigger is triggered. Otherwise, all alarm messages are<br />

buffered and sent in only one email when the Send Trigger is triggered. You cannot<br />

disable (uncheck) this option when the Subject option is configured with "Use alarm<br />

message".<br />

When checking this option, the emails are removed from the buffer after attempting to<br />

send them, even if there was an error (failure) and the email was not sent. Otherwise,<br />

Text and/or {Tag} (up to 1024 chars)<br />

Radio-button / Text (up to 1024 chars)<br />

Checkbox<br />

checkbox<br />