About remote management<br />

c) Set Remote Agent to automatically run at start up by creating a link to it in \Windows\Startup on the<br />

target device.<br />

d) Run Remote Agent.<br />

The Remote Agent window is displayed.<br />

3. Configure the communication settings in Remote Agent.<br />

a) Click Setup.<br />

The Setup dialog box is displayed.<br />

b) Select the appropriate connection type: Serial Port or TCP/IP. If you select Serial Port, then also select the<br />

COM port and verify the advanced serial communication settings.<br />

If you are already connected to the target system via ActiveSync, then you do not need to select another<br />

connection at this time. However, keep in mind how the target system will actually be used during<br />

project run time.<br />

c) Click OK.<br />

d) If you selected TCP/IP for the device connection, then note the IP address.<br />

e) Make sure that you leave Remote Agent running on the target system.<br />

4. Use the Remote Management tool to connect to the target system.<br />

a) Run the project development application on your computer.<br />

b) On the Home tab of the ribbon, in the Remote Management group, click Connect.<br />