Installation<br />

The Remote Management dialog box is displayed.<br />

c) Select the appropriate connection type for the target system: Network IP, Serial Port, or Microsoft ActiveSync. If<br />

you select Network IP, then also type the IP address of the target system. If you select Serial Port, then also<br />

select the COM port and verify the advanced serial communication settings.<br />

d) Click Connect.<br />

If you are successfully connected, then the connection status is shown in the Status box and the target<br />

system's specifications are shown in the Platform box. If you are not connected, then check both the<br />

connection settings and the physical connections.<br />

Note: In some cases, the Remote Management tool may not be able to connect via Microsoft<br />

ActiveSync to a device running Windows CE 6.0 or later. This is because of a problem in the<br />

default configuration of Windows CE 6.0. You can fix the problem by using a small utility that<br />

is included with <strong>InduSoft</strong> Web Studio. The utility is located at:<br />

C:\Program Files\<strong>InduSoft</strong> Web Studio v7.1\Redist\ActiveSyncUnlock.exe<br />

Copy this file to the device using the stand-alone version of Microsoft ActiveSync and then<br />

execute the file on the device. It does not matter where on the device the file is located. When<br />

this is done, try again to use the Remote Management tool to connect to the device.<br />

If you still cannot connect via Microsoft ActiveSync, then empty the device's \Temp directory<br />

and try again.<br />

5. Install the rest of the EmbeddedView or CEView software on the target system.<br />

a) In Remote Management, click Install system files.<br />

When the installation is finished, the target system's updated status is displayed in the Status box.<br />

With EmbeddedView or CEView installed on the target system, you can now use it as a project runtime server<br />

and/or client.<br />

Note: The following run-time features are supported by the full <strong>InduSoft</strong> Web Studio software but<br />

not by EmbeddedView and CEView:<br />

• DDE task worksheets.<br />

• ODBC task worksheets and built-in functions. (ADO interface is supported.)<br />

• Third-party .NET controls.<br />

• OPC HDA Server.<br />

• OPC UA and OPC .NET clients<br />

• Some minor graphic features, such as fill effects for shapes other than rectangle, picture formats<br />

other than BMP or JPG, and Ellipse style.<br />

• Some built-in functions. For more information, see the individual function descriptions.<br />

<strong>InduSoft</strong> Web Studio Page 39