Creating a New Project<br />

Database in the local station to save data temporarily if the Primary Database is not available (during a<br />

network failure, for instance).<br />

• Use project default checkbox: When this option is checked, IWS uses the settings configured in the Default<br />

Database for the task that is being configured (Connection string, User name, Password, Retry Interval and<br />

Advanced Settings). When this option is not checked, you can configure these settings individually to the<br />

current task.<br />

• Connection string field: This field defines the database where IWS will write and read values as well as<br />

the main parameters used when connecting to the database. Instead of writing the Connection string<br />

manually, you can press the browse button (…) and select the database type from the Data Link Properties<br />

window.<br />

Data Link Properties dialog<br />

Note: The list of Database Providers shown in the Data Link Properties window depends on the<br />

providers actually installed and available in the computer where you are running IWS. Consult<br />

the operating system documentation (or the database documentation) for further information<br />

regarding the settings of the Provider for the database that you are using.<br />

• User name field: User name used to connect to the database. The user name configured in this field must<br />

match the user name configured in the database.<br />

• Password field: Password used to connect to the database. The password configured in this field must match<br />

the password configured in the database.<br />

• Retry Interval field: If IWS is unable to connect to the database for any reason, it retries automatically to<br />

connect to the database after the number of seconds configured in this field have passed.<br />

• Advanced button: After pressing this button, you have access to customize some settings. For most projects,<br />

the default value of these settings do not need to be modified and should be kept.<br />

Database Configuration: Advanced dialog<br />