Communication with Other Devices<br />

Solution: The first step is to create a single user in both computers that has Administrator privileges and the<br />

same password. Log on with this user to both ends, and then try to establish the connection.<br />

If you cannot use the same user in both computers because of some specific requirement of your project, or if<br />

the problem persists even after you have logged on as the same user, please read the documents below. They<br />

will help you solve the security issues:<br />

• DCOM Security Configuration (external link)<br />

• Using DCOM with Windows XP + SP2 (external link)<br />

Name Resolution<br />

Error: Couldn't create connection with advise sink, error: -2147022986 (0x80070776)<br />

Reason for error: There is a problem resolving the computer name.<br />

Solution: This problem can be solved by specifying the IP address of the server instead of specifying the<br />

computer name.<br />

Proxy for Windows CE<br />

Error: OPCServer: IIndCP::Advise - Could not query callback interface: 0x80040155<br />

Reason for error: Your Windows Embedded device is missing the OPCCOMN_PS.dll.<br />

Solution: You should download the .dll to the device and register it. The .dll should be available with your IWS<br />

distribution, most probably in […]\<strong>InduSoft</strong> Web Studio v7.1\Redist\Wince x.x\processor\<br />

If you do not find the .dll in the folder for your processor, contact your IWS distributor.<br />