Tags and the Project Database<br />

Using the Object Finder to select integrated tags<br />

After you have added a tag integration source to your project, the tags from that source can be viewed and<br />

selected in the Object Finder like any other project tags.<br />

The integrated tags are listed in the Object Finder tree-view under Devices, with each device being a tag<br />

integration source that you added. The names of the devices are those that you specified when you added<br />

them.<br />

Devices are shown with three possible icons:<br />

Browsing integrated tags in the Object Finder<br />

Icon<br />

Description<br />

Device tag information was extracted from a symbol file and then cached.<br />

Device tag information is currently being received from a connected device.<br />

Connection to device has failed. Tag information might not be up-to-date.<br />

The folder structure for each device is determined by the PLC or source project, and the individual tags are<br />

listed to the right.<br />

Note: IWS does not support pointer variables from devices. They will be shown in the Object Finder<br />

with the rest of the device tags, but they will be marked with a red X icon to indicate that they<br />

cannot be used.<br />

To refresh the device tag information — either by rereading the symbol file or by trying to reconnect to the<br />

device — click Refresh Devices on the right side of the window. All configured devices will be refreshed at the<br />

same time.<br />

Changes in the device tag information might break tag references in your project. To find broken tag<br />

references, verify your project: on the Home tab of the ribbon, click Verify.<br />

How integrated tags may be renamed in your project<br />

When IWS integrates tags from third-party devices and software, it cannot directly transcribe the tag names.<br />

Some changes are made to improve tag management and to adhere to the local tag name syntax.<br />

Tip: The full, original name of an integrated tag can always be retrieved by referencing the<br />

DeviceTag property on the tag. For example, tagname->DeviceTag.<br />