Communication with Other Devices<br />

Area / Element<br />

Description<br />

Write actions<br />

Asynchronous read<br />

trigger<br />

Read count<br />

Status<br />

Status message<br />

Maximum aging<br />

Enable write on tag<br />

change<br />

N/A for OPC .Net Client.<br />

The name of a tag (Integer type) that will receive a count of the number of read operations performed<br />

since the project was run.<br />

The name of a tag (Integer type) that will receive a status code for the last read operation performed by<br />

a trigger.<br />

The name of a tag (String type) that will receive the corresponding status message.<br />

N/A for OPC .Net Client.<br />

When this value is TRUE (non-zero), a write will be automatically performed whenever the value of the<br />

project tag changes.<br />

Note: This is enabled by default. If it is disabled, then you must use a write trigger (see<br />

below).<br />

Reload trigger<br />

Refresh IDs on startup<br />

Enable bit notation<br />

Maximum group size<br />

Synchronous write<br />

trigger<br />

Asynchronous write<br />

trigger<br />

Write count<br />

Status<br />

Status message<br />

The maximum number of tag writes to be performed in a single write operation.<br />

For example, if you have 1000 items/rows configured in the worksheet and Maximum group size is set<br />

to 100, then 10 write operations will be performed during each scan of the worksheet.<br />

When the value of this tag/expression changes, the worksheet is scanned and all tag values are written<br />

to the server. The project waits for the scan to complete before continuing.<br />

N/A for OPC .Net Client.<br />

The name of a tag (Integer type) that will receive a count of the number of write operations performed<br />

since the project was run.<br />

The name of a tag (Integer type) that will receive a status code for the last write operation performed by<br />

a trigger.<br />

The name of a tag (String type) that will receive the corresponding status message.<br />

Indirect tags (e.g., {MyTag}) configured in the body of the worksheet will be reloaded only when the<br />

value of this tag/expression changes.<br />

N/A for OPC .Net Client.<br />

When this option is selected, bit notation is allowed in the Item column of the worksheet body.<br />

5. Click OK to close the Advanced dialog and return to the worksheet.<br />

6. In the Status box, type the name of a tag (Integer type) that will receive connection status codes during<br />

project runtime.<br />

7. In the Status Message box, type the name of a tag (String type) that will receive the corresponding status<br />

messages.<br />

8. In the Publish Rate box, type the frequency (in milliseconds) at which the client will request updates from the<br />

server.<br />

9. In the Disable box, type a tag/expression. When the value is TRUE (non-zero), the worksheet will not be<br />

executed.<br />

10.In the Root node or view box, specify the server node that will serve as the root for all items in the worksheet<br />

body. Specifying a root node makes it easier to find items and improves runtime performance.<br />

11.For each row of the worksheet body, specify the following:<br />

• Tag Name: The name of a project tag.<br />

You may use indirect tags (e.g., {MyTag}), but if you do, then be sure to configure the Reload trigger<br />

option above.<br />

• Item: The server item with which the project tag should be associated.<br />

To browse the server's list of items, right-click in this field and then click Browse on the shortcut menu.<br />

<strong>InduSoft</strong> Web Studio Page 349