About thin clients and mobile access<br />

3. Copy the files to non-volatile memory on the Windows Embedded device.<br />

4. Register the ISSymbol control on the Windows Embedded device by executing the following command from<br />

the Prompt window:<br />

regsvrce.exe "\ISSymbolPath\ISSymbolCE.ocx"<br />

Example:<br />

regsvrce.exe "\Storage Card\ISSymbolCE.ocx"<br />

5. Save the registry settings to keep ISSymbolCE.ocx registered when you reboot the Windows Embedded<br />

device.<br />

Tip: Check the device manufacturer's documentation for how to save the registry settings.<br />

6. Start the Secure Viewer by running Viewer.exe.<br />

Changing the Secure Viewer Configuration<br />

After initial installation, the configuration of the Secure Viewer is saved in the viewer.ini file, which should be<br />

in the same directory as Viewer.exe. (This should be in the \Bin sub-folder where the Secure Viewer program<br />

is installed). There are two ways to change the configuration of the Secure Viewer after it has been installed.<br />

First, you can run the Viewer configuration utility (ViewerCfg.exe) that was also installed.<br />

Note: On WIndows Vista and Windows 7, the Secure Viewer configuration utility must have<br />

Administrator privileges to run properly. It should be installed with those privileges by default, but<br />

if you still have problems, then check the file properties for ViewerCfg.exe and make sure Run as<br />

Administrator is selected.<br />

The configuration utility provides the following options:<br />

• Save button: Immediately save the current settings to a viewer.ini in the same directory as the<br />

ViewerCfg.exe utility.<br />

• Import button: Load a viewer.ini file from another directory.<br />

• Export button: Save the viewer.ini file to another directory.<br />

• Data Server IP field: Enter the IP address (or host name) of your data server station.<br />

The data server station is the computer or device where the TCP/IP Server module is running.<br />

• TCP Port field: Enter the port number of the Data Server, if it is different than the default port of 1234.<br />

• URL field: Enter the URL or filepath of the project file (*.app) on the Web Server.<br />

• Enable Splash Window option: Check (enable) this option to see a splash window when you start the<br />

Secure Viewer.<br />

• Enable Progress Bar option: Check (enable) this option to see a progress bar while the Secure Viewer<br />

loads the project file.<br />