4-10<br />

MAINTENANCE ORBAN MODEL <strong>9400</strong><br />

D) Inject the Analog Input XLR connector with a level of +10 dBu with the oscillator<br />

set to 100 Hz.<br />

E) Connect the audio analyzer to the <strong>9400</strong>'s Left Analog Output XLR connector.<br />

F) Verify a level of +10 dBu ±1 dB. Use this level as the reference level.<br />

G) Verify that frequency response at 50 Hz, 100 Hz, 400 Hz, 5 kHz, and 15 kHz is<br />

within ±0.1 dB of the reference level.<br />

This procedure tests the analog input circuitry, the A/D converter, the<br />

DSP, the DAC, and the analog output circuitry.<br />

H) Repeat steps (C) through (G) for the right channel.<br />

5. Check distortion performance of Analog I/O.<br />

A) Verify <strong>9400</strong> software controls are set to their default settings. (Refer to page<br />

4-7.)<br />

B) Be sure you are still in BYPASS mode [see step (3.F)].<br />

C) Connect a THD analyzer to the Left Analog Output #1 XLR connector. Set the<br />

THD analyzer's bandwidth to 22 kHz.<br />

D) Connect the oscillator to the Left Analog Input XLR connector.<br />

E) For each frequency used to measure THD, adjust the output level of the oscillator<br />

to make the COMP meter on the <strong>9400</strong> read 100.<br />

F) Measure the THD+N at the frequency levels listed below.<br />

Frequency THD+N Typical THD+N Maximum<br />

50 Hz 0.015% 0.03%<br />

100 Hz 0.015% 0.03%<br />

400 Hz 0.015% 0.03%<br />

1 kHz 0.015% 0.03%<br />

2.5 kHz 0.015% 0.03%<br />

5 kHz 0.015% 0.03%<br />

7.5 kHz 0.015% 0.03%<br />

15 kHz 0.015% 0.03%<br />

G) Repeat the above measurements for the right channel. Connect the oscillator<br />

to the right analog input and the distortion analyzer to the right analog output.<br />

H) Repeat these measurements for the left and right channels of Analog Output<br />

#2.<br />

I) Disconnect the oscillator and THD analyzer from the <strong>9400</strong>.<br />

6. Test Digital Sample Rate Converter (Receiver).<br />

A) Verify <strong>9400</strong> software controls are set to their default settings. (Refer to page<br />

4-7.)