OPTIMOD-<strong>AM</strong> DIGITAL TECHNICAL DATA 6-3<br />

Source Impedance: Electronically balanced and floating outputs simulate a true transformer<br />

output. Because of the built-in third-order EMI suppression filter, the source impedance<br />

is 351. Loading the output with 600 will decrease the output level by 4.0 dB<br />

compared to a high impedance (bridging) load and will reduce the maximum available<br />

output level by 4.0 dB. A software switch in Analog Output screen allows the output level<br />

calibration to be set for a bridging or 600 load.<br />

Load Impedance: 600 or greater, balanced or unbalanced. Termination not required or<br />

recommended.<br />

Output Level (100% peak modulation): Adjustable from –6 dBu to +20 dBu peak, into 600<br />

or greater load, software-adjustable.<br />

Signal-to-Noise: >= 90 dB unweighted (Bypass mode, de-emphasized, 20 Hz–9.5 kHz<br />

bandwidth, referenced to 100% modulation).<br />

L/R Crosstalk: