2-28<br />
INSTALLATION ORBAN MODEL <strong>9400</strong><br />
filter cutoff frequency. By making the transition between the passband and<br />
stopband progressively more rounded and gentle, each step trades off duller<br />
sound against less ringing. See Figure 2-8.<br />
D) Hold down the soft key under HIGHPASS AND Select the highpass filter cutoff<br />
frequency you need by turning the knob.<br />
OPTIMOD-<strong>AM</strong> can be programmed for any highpass filter cutoff frequency<br />
from 50 to 100Hz in 10Hz steps. Default is 50 Hz. See the text in<br />
step (6.B) on page 2-18 for guidance on where to set the frequency. Refer<br />
to the text in step (B) on page 2-26 regarding global system settings<br />
vs. setting in presets.<br />
E) Set the lowpass and highpass filter cutoff frequencies for any other Transmission<br />
Presets you will be using. Note that each preset has an independent setting<br />
for lowpass cutoff, lowpass shape, highpass cutoff, and asymmetry.<br />
a) Press ESC.<br />
b) Press the soft key labeled with the transmission preset you wish to adjust.<br />
c) Adjust the filter frequencies as you did in the steps above.<br />
8. Configure analog output(s).<br />
[Skip this step if you will not be using the analog output(s).]<br />
A) Navigate to SETUP > IO CALIB > OUTPUT > ANALOG1.<br />
If necessary, use the NEXT button to scroll horizontally.<br />
B) Set the SOURCE to <strong>AM</strong> PROC, HD PROC, or MONITOR.<br />
<strong>AM</strong> PROC feeds the selected output with the output of the processing<br />
chain for analog <strong>AM</strong> transmitters. HD PROC feeds the selected output<br />
with the output of the processing chain for HD Radio or other digital<br />
transmission channels like netcasts.<br />
C) Set the LOAD control to BRIDGING or 600 OHMS. The normal setting is BRIDGING.<br />
Only set this control to 600 OHMS if your transmitter has been verified to have<br />
a 600-ohm input impedance.<br />
Functionally, the control increases the output level by 4.0 dB when the<br />
control is changed from BRIDGING to 600 OHM. This compensates for the 4<br />
dB loss in the <strong>9400</strong>’s EMI filtering network when this network is loaded<br />
by 600 ohms.<br />
If you are using Analog Output #2, navigate to Navigate to SETUP > IO<br />
CALIB > OUTPUT > ANALOG2 and repeat this step.<br />
9. Configure digital output(s).<br />
[Skip this step if you will not be using the digital output(s).]<br />
A) Navigate to SETUP > IO CALIB > OUTPUT > DIGITAL1.<br />
If necessary, use the NEXT button to scroll horizontally.<br />
B) Set the SOURCE to <strong>AM</strong> PROC, HD PROC, or MONITOR.