Technical Data<br />
■ Technical data<br />
SIPART PS2<br />
SIPART PS2 EEx d<br />
General data<br />
Travel range (linear actuators)<br />
Angle or rotation (part-turn<br />
actuators)<br />
Installation<br />
• On linear actuators<br />
• On part-turn actuators<br />
3 to 130 mm ( 0.12 to 5.12 inch)<br />
(angle of feedback shaft 16 to<br />
90°)<br />
30 to 100°<br />
Using mounting kit 6DR4004-8V<br />
and additional lever arm<br />
6DR4004-8L if required on actuators<br />
according to IEC 534-6<br />
(NAMUR) with ledge, columns or<br />
plane surface<br />
Using mounting kit 6DR4004-8D<br />
on actuators with fixing platform<br />
according to VDI/VDE 3845 and<br />
DIN 3337:<br />
the mounting plate must be provided<br />
on the actuator side;<br />
shaft with nut and M6 female<br />
thread (see Fig. 5/16)<br />
Controller<br />
• Five-point switch<br />
Self-adjusting<br />
• Dead zone<br />
dEbA = Auto<br />
Self-adjusting or<br />
dEbA = 0.1 to 10%<br />
fixed setting<br />
• Controllable response time ≥ 1.5 s,<br />
reduced resolution with smaller<br />
positioning times<br />
A/D converter<br />
• Scanning time<br />
10 ms<br />
• Resolution ≤ 0.05%<br />
• Transmission error ≤ 0.2%<br />
• Temperature influence<br />
≤ 0.1%/10 K (≤ 0.1%/18 °F)<br />
Binary input BI1 (terminals 9/10;<br />
electrically connected to basic<br />
device)<br />
Degree of protection<br />
Mounting position<br />
CE marking<br />
EMC requirements<br />
Can only be used for <strong>flo</strong>ating contact;<br />
max. contact rating < 5 µA at<br />
3 V<br />
IP 65 to EN 60 529/NEMA 4x<br />
Any; in wet environment, pneumatic<br />
connections and exhaust<br />
opening not upwards<br />
Conforms to EMC guideline<br />
89/336 EEC in compliance with<br />
the following standards<br />
EN 61 326/A1 Appendix A.1 and<br />
NAMUR NE21 August 1998<br />
1 ) When commissioning at ≤ 0 °C (≤ 32 °F) make sure that the <strong>valves</strong> are<br />
purged with the dry medium for a sufficiently long time.<br />
2 ) Limited refresh rate of LCD below -10 °C (+14 °F). Only T4 permissible<br />
when using with Iy module.<br />
3 ) With the EEx d version (6DR5 7 7 5-...), the values are reduced by<br />
approx. 20%.<br />
Technical data (continued)<br />
Material of:<br />
•Casing<br />
-6DR5 770-... (plastic)<br />
-6DR5 771-... (metal)<br />
-6DR5 775-... (metal)<br />
• Pressure gauge block<br />
Vibration resistance<br />
• Harmonic oscillations (sine-wave)<br />
according to DIN EN 60 062-2-6/<br />
05.96<br />
• Repetitive shocks (half sine-wave)<br />
according to DIN EN 60 068-2-29/<br />
03.95<br />
• Noise (digitally <strong>control</strong>led) according<br />
to DIN EN 60 068-2-64/08.95<br />
• Recommended continuous range<br />
of use for complete fitting<br />
Weight, basic device<br />
• Plastic casing<br />
• Metal casing<br />
• Metal casing, EEx d version<br />
Glass-fiber-reinforced Macrolon<br />
GK-AISi12<br />
GK-AISi12<br />
Aluminium AIMgSi, anodized<br />
3.5 mm (0.14 inch) (2 to 27 Hz)<br />
3 cycles/axis<br />
98.1 m/s 2 (321.84 ft/s 2 )<br />
(27 to 300 Hz) 3 cycles/axis<br />
150 m/s 2 (492 ft/s 2 ), 6 ms<br />
1000 shocks/axis<br />
10 to 200 Hz 1 (m/s 2 ) 2 /Hz<br />
(3.28 (ft/s 2 ) 2 /Hz)<br />
200 to 500 Hz 0.3 (m/s 2 ) 2 /Hz<br />
(0.98 (ft/s 2 ) 2 /Hz)<br />
4 hours/axis<br />
≤ 30 m/s 2 (≤ 98.4 ft/s 2 ) without<br />
magnification factor<br />
Approx. 0.9 kg (1.98 lb)<br />
Approx. 1.3 kg (2.87 lb)<br />
Approx. 5.2 kg (11.46 lb)<br />
Dimensions See Fig. 5/14 and Fig. 5/15<br />
Climatic class To IEC 721<br />
•Storage 1K5, but -40 to +80 °C 1 )<br />
(1K5, but -40 to +176 °F 1 ))<br />
• Transport 2K4, but -40 to +80 °C 1 )<br />
(2K4, but -40 to +176 °F 1 ))<br />
•Operation<br />
- Without purging air 3K3, but -30 to +80 °C 2 )<br />
(3K3, but -22 to +176 °F 2 ))<br />
- With purging air 3K4, but -30 to +80 °C 2 )<br />
(3K4, but -22 to +176 °F 2 ))<br />
Certificates and approvals<br />
Classification according to pressure<br />
equipment directive<br />
(DGRL 97/23/EC)<br />
Pneumatic data<br />
Supply (inlet air)<br />
• Pressure<br />
For gases of fluid group 1 and<br />
liquids of fluid group 1, complies<br />
with requirements of article 3,<br />
paragraph 3 (sound engineering<br />
practice SEP)<br />
1.4 to 7 bar (20.3 to 101.5 psi):<br />
sufficiently larger than max. actuator<br />
pressure (positioning pressure)<br />
Air quality according to ISO 8573-1<br />
• Size and density of particulates Class 2<br />
• Pressure dew point<br />
Class 2 (min. 20 K (36 °F) below<br />
ambient temperature)<br />
• Oil concentration Class 2<br />
Unrestricted <strong>flo</strong>w of: At 2 bar 4 bar 6 bar<br />
(29 psi) (58 psi) (87 psi)<br />
• Inlet air valve [Nm 3 /h] (USgpm) 3 ) 4.1 7.1 9.8<br />
(18.1) (31.3) (43.1)<br />
• Outlet air valve [Nm 3 /h] (USgpm) 3 ) 8.2 13.7 19.2<br />
(36.1) (60.3) (84.5)<br />
Valve leakage<br />
< 6 x 10 -4 Nm 3 /h (0.0026 USgpm)<br />
Throttle ratio Adjustable up to ∞ : 1<br />
Consumption of inlet air in<br />
stable state<br />
Types of actuators<br />
• In plastic casing<br />
• In metal casing<br />
• In flameproof casing<br />
< 3.6 x 10 -2 Nm 3 /h<br />
(0.158 USgpm)<br />
Single-action and double-action<br />
Single-action<br />
Single-action and double-action<br />
114<br />
SIPART PS2 Manual<br />
A5E00074631-03