Technical Data<br />

■ Technical data<br />

SIPART PS2<br />

SIPART PS2 EEx d<br />

General data<br />

Travel range (linear actuators)<br />

Angle or rotation (part-turn<br />

actuators)<br />

Installation<br />

• On linear actuators<br />

• On part-turn actuators<br />

3 to 130 mm ( 0.12 to 5.12 inch)<br />

(angle of feedback shaft 16 to<br />

90°)<br />

30 to 100°<br />

Using mounting kit 6DR4004-8V<br />

and additional lever arm<br />

6DR4004-8L if required on actuators<br />

according to IEC 534-6<br />

(NAMUR) with ledge, columns or<br />

plane surface<br />

Using mounting kit 6DR4004-8D<br />

on actuators with fixing platform<br />

according to VDI/VDE 3845 and<br />

DIN 3337:<br />

the mounting plate must be provided<br />

on the actuator side;<br />

shaft with nut and M6 female<br />

thread (see Fig. 5/16)<br />

Controller<br />

• Five-point switch<br />

Self-adjusting<br />

• Dead zone<br />

dEbA = Auto<br />

Self-adjusting or<br />

dEbA = 0.1 to 10%<br />

fixed setting<br />

• Controllable response time ≥ 1.5 s,<br />

reduced resolution with smaller<br />

positioning times<br />

A/D converter<br />

• Scanning time<br />

10 ms<br />

• Resolution ≤ 0.05%<br />

• Transmission error ≤ 0.2%<br />

• Temperature influence<br />

≤ 0.1%/10 K (≤ 0.1%/18 °F)<br />

Binary input BI1 (terminals 9/10;<br />

electrically connected to basic<br />

device)<br />

Degree of protection<br />

Mounting position<br />

CE marking<br />

EMC requirements<br />

Can only be used for <strong>flo</strong>ating contact;<br />

max. contact rating < 5 µA at<br />

3 V<br />

IP 65 to EN 60 529/NEMA 4x<br />

Any; in wet environment, pneumatic<br />

connections and exhaust<br />

opening not upwards<br />

Conforms to EMC guideline<br />

89/336 EEC in compliance with<br />

the following standards<br />

EN 61 326/A1 Appendix A.1 and<br />

NAMUR NE21 August 1998<br />

1 ) When commissioning at ≤ 0 °C (≤ 32 °F) make sure that the <strong>valves</strong> are<br />

purged with the dry medium for a sufficiently long time.<br />

2 ) Limited refresh rate of LCD below -10 °C (+14 °F). Only T4 permissible<br />

when using with Iy module.<br />

3 ) With the EEx d version (6DR5 7 7 5-...), the values are reduced by<br />

approx. 20%.<br />

Technical data (continued)<br />

Material of:<br />

•Casing<br />

-6DR5 770-... (plastic)<br />

-6DR5 771-... (metal)<br />

-6DR5 775-... (metal)<br />

• Pressure gauge block<br />

Vibration resistance<br />

• Harmonic oscillations (sine-wave)<br />

according to DIN EN 60 062-2-6/<br />

05.96<br />

• Repetitive shocks (half sine-wave)<br />

according to DIN EN 60 068-2-29/<br />

03.95<br />

• Noise (digitally <strong>control</strong>led) according<br />

to DIN EN 60 068-2-64/08.95<br />

• Recommended continuous range<br />

of use for complete fitting<br />

Weight, basic device<br />

• Plastic casing<br />

• Metal casing<br />

• Metal casing, EEx d version<br />

Glass-fiber-reinforced Macrolon<br />

GK-AISi12<br />

GK-AISi12<br />

Aluminium AIMgSi, anodized<br />

3.5 mm (0.14 inch) (2 to 27 Hz)<br />

3 cycles/axis<br />

98.1 m/s 2 (321.84 ft/s 2 )<br />

(27 to 300 Hz) 3 cycles/axis<br />

150 m/s 2 (492 ft/s 2 ), 6 ms<br />

1000 shocks/axis<br />

10 to 200 Hz 1 (m/s 2 ) 2 /Hz<br />

(3.28 (ft/s 2 ) 2 /Hz)<br />

200 to 500 Hz 0.3 (m/s 2 ) 2 /Hz<br />

(0.98 (ft/s 2 ) 2 /Hz)<br />

4 hours/axis<br />

≤ 30 m/s 2 (≤ 98.4 ft/s 2 ) without<br />

magnification factor<br />

Approx. 0.9 kg (1.98 lb)<br />

Approx. 1.3 kg (2.87 lb)<br />

Approx. 5.2 kg (11.46 lb)<br />

Dimensions See Fig. 5/14 and Fig. 5/15<br />

Climatic class To IEC 721<br />

•Storage 1K5, but -40 to +80 °C 1 )<br />

(1K5, but -40 to +176 °F 1 ))<br />

• Transport 2K4, but -40 to +80 °C 1 )<br />

(2K4, but -40 to +176 °F 1 ))<br />

•Operation<br />

- Without purging air 3K3, but -30 to +80 °C 2 )<br />

(3K3, but -22 to +176 °F 2 ))<br />

- With purging air 3K4, but -30 to +80 °C 2 )<br />

(3K4, but -22 to +176 °F 2 ))<br />

Certificates and approvals<br />

Classification according to pressure<br />

equipment directive<br />

(DGRL 97/23/EC)<br />

Pneumatic data<br />

Supply (inlet air)<br />

• Pressure<br />

For gases of fluid group 1 and<br />

liquids of fluid group 1, complies<br />

with requirements of article 3,<br />

paragraph 3 (sound engineering<br />

practice SEP)<br />

1.4 to 7 bar (20.3 to 101.5 psi):<br />

sufficiently larger than max. actuator<br />

pressure (positioning pressure)<br />

Air quality according to ISO 8573-1<br />

• Size and density of particulates Class 2<br />

• Pressure dew point<br />

Class 2 (min. 20 K (36 °F) below<br />

ambient temperature)<br />

• Oil concentration Class 2<br />

Unrestricted <strong>flo</strong>w of: At 2 bar 4 bar 6 bar<br />

(29 psi) (58 psi) (87 psi)<br />

• Inlet air valve [Nm 3 /h] (USgpm) 3 ) 4.1 7.1 9.8<br />

(18.1) (31.3) (43.1)<br />

• Outlet air valve [Nm 3 /h] (USgpm) 3 ) 8.2 13.7 19.2<br />

(36.1) (60.3) (84.5)<br />

Valve leakage<br />

< 6 x 10 -4 Nm 3 /h (0.0026 USgpm)<br />

Throttle ratio Adjustable up to ∞ : 1<br />

Consumption of inlet air in<br />

stable state<br />

Types of actuators<br />

• In plastic casing<br />

• In metal casing<br />

• In flameproof casing<br />

< 3.6 x 10 -2 Nm 3 /h<br />

(0.158 USgpm)<br />

Single-action and double-action<br />

Single-action<br />

Single-action and double-action<br />

114<br />

SIPART PS2 Manual<br />

A5E00074631-03