No.<br />
Part name<br />
Procedures<br />
Remarks<br />
7<br />
Fan motor<br />
1) Follow to the procedure in the item 3 .<br />
2) Loosen the set screw of the cross flow fan.<br />
3) Remove two fixing screws of the motor band<br />
(Right), and then remove the motor band<br />
(Right).<br />
4) Pull the fan motor outward.<br />
In assembling work, install the fan motor as<br />
follows.<br />
• When assembling the fan motor, the fan<br />
motor must be installed in such a way that<br />
the fan motor leads will be taken out is<br />
positioned at the bottom front.<br />
• After assembling the two hooking claws of<br />
the motor band (right) into the main body,<br />
position the fan motor, insert it, and then<br />
secure the motor band (right) using the two<br />
fixing screws.<br />
Set screw<br />
Secure using<br />
the fixing screw<br />
Screw<br />
Motor band (Right)<br />
Screw<br />
Secure using<br />
the fixing screw<br />
Fan motor leads<br />
8<br />
Cross flow fan<br />
1) Follow to the procedure in the item 6 .<br />
2) Remove the heat exchanger fixing holder by<br />
removing the two fixing screws used to<br />
secure it.<br />
3) Loosen the set screw of the cross flow fan.<br />
4) Lift the left side of the heat exchanger, and<br />
pull out the cross flow fan.<br />
Raise the<br />
left side<br />
Pull out here<br />
– 113 –