7. REFRIGERANT CYCLE DIAGRAM<br />

RAS-B10GKVP-E, RAS-B13GKVP-E, RAS-B16GKVP-E / RAS-4M27GAV-E<br />

To<br />

D room<br />

Temp. measurement<br />

To<br />

C room<br />

To<br />

B room<br />

T1<br />

Indoor unit A<br />

Evaporator<br />

TCa<br />

To<br />

D room<br />

To<br />

C room<br />

To<br />

B room<br />

Connecting pipe<br />

Thickness : 0.8mm<br />

Ø12.7 :<br />

RAS-B16GKVP-E<br />

Ø9.52 :<br />

RAS-B10GKVP-E<br />

RAS-B13GKVP-E<br />

Cross flow fan<br />

TA<br />

Connecting pipe<br />

Thickness : 0.8mm<br />

Ø6.35<br />

Allowable height<br />

difference : 15m<br />

Allowable pipe length<br />

Sectional shape<br />

of heat insulator<br />

(Ø9.52) (Ø9.52) (Ø9.52) (Ø12.7) (Ø6.35) (Ø6.35) (Ø6.35) (Ø6.35)<br />

Per 1 unit<br />

Max. : 25m<br />

Min. : 2m<br />

Total<br />

Max. : 70m<br />

Strainer<br />

TGd TGc TGb<br />

TGa<br />

Pulse motor<br />

valve at liquid side<br />

(UKV-18D)<br />

P<br />

Pressure<br />

measurement<br />

Gauge attaching port<br />

Vacuum pump<br />

connecting port<br />

Packed valve (Gas side)<br />

(Ø12.7)<br />

Packed valve (Liquid side)<br />

(Ø9.52)<br />

Accumulating<br />

tank 1500cc<br />

TS<br />

Muffler<br />

Ø25 x 160L<br />

TD<br />

Compressor<br />

DA220A2F-20L<br />

TE<br />

Temp. measurement<br />

T2<br />

Propeller fan<br />

TO<br />

Refrigerant amount : 2.4kg (R410A)<br />

Outdoor unit<br />

NOTE :<br />

Gas leak check position<br />

Refrigerant flow (Cooling)<br />

Refrigerant flow (Heating)<br />

NOTE :<br />

• The maximum pipe length of this air conditioner is 70 m. The additional charging of refrigerant is unnecesary<br />

because this conditioner is designed with charge-less specification.<br />

• Connection of only one indoor unit is unavailable. Two or more indoor units should be connected.<br />