12-3. Outdoor Unit<br />

No.<br />

Part name<br />

Procedure<br />

Remarks<br />

1<br />

Common<br />

procedure<br />

1. Detachment<br />

1) Stop operation of the air conditioner, and turn<br />

“OFF” the power breaker.<br />

2) Remove the side panel. (Ø4 × 10L 3 pcs.)<br />

3) Remove the cord clamp.<br />

(Ø4 × 14L 5 × 2 = 10 pcs.)<br />

Disconnect the connecting cables and power<br />

cord from the terminals.<br />

4) Remove the upper panel. (Ø4 × 10L 6 pcs.)<br />

5) Remove the front panel. (Ø4 × 10L 3 pcs.)<br />

6) Remove the back panel. (Ø4 × 10L 6 pcs.)<br />

7) Remove the air outlet panel. (Ø4 × 10L 8 pcs.)<br />

Air outlet panel<br />

Fan<br />

guard<br />

4<br />

Front panel<br />

Upper panel<br />

Back panel<br />

Side panel<br />

2 Inverter<br />

assembly<br />

1. Detachment<br />

1) Perform work from item 1) to 5) of 1 .<br />

2) Remove screw (ST1T Ø4 × 10L 1 pc.) of the<br />

upper left part of the inverter cover.<br />

• If removing the inverter cover in this condition,<br />

P.C. board can be checked.<br />

• If there is no space in the upper part of the<br />

upper cabinet, perform work from 6) to 7) of<br />

1 and remove the partition fixing plate<br />

(ST1T Ø4 × 10L 1 pc.).<br />

Be careful to check the inverter because<br />

high-voltage circuit is incorporated in it.<br />

3) Perform discharging by connecting the discharging<br />

resistance (approx. 100Ω 40W) or<br />

plug of soldering iron to , terminals of the<br />

C15 (printed “CAUTION HIGH VOLTAGE” is<br />

attached.) electrolytic capacitor (760µF) on<br />

P.C. board.<br />

Be careful to discharge the capacitor because<br />

the electrolytic capacitor cannot<br />

naturally discharge and voltage remains<br />

according to trouble type in some cases.<br />

Inverter cover<br />

P.C. board<br />

(Soldered surface)<br />

Fixing plate<br />

(Partition)<br />

NOTE<br />

This capacitor is one with mass capacity.<br />

Therefore, it is dangerous that a large spark<br />

generates if short-circuiting between ,<br />

polarity with screwdriver, etc. for discharging.<br />

The holder at upper part.<br />

4) Remove screw (Ø4 × 10L 2 pcs.) fixing the<br />

valve clamping plate/the inverter box, and<br />

fixing the back panel/the inverter box.<br />

5) Remove various lead wires from the holder at<br />

upper part of the inverter box and cut 2 tie-lap<br />

ties binding each lead wires :<br />

6) Pull the inverter box upward.<br />

7) Disconnect connectors of various lead wires.<br />

Tie-lap ties (2 pcs)<br />