8-2. Outdoor Unit (Inverter Assembly)<br />

RAS-4M27GAV-E, RAS-4M27GACV-E, RAS-3M26GAV-E<br />

Outdoor air temp. Sensor<br />

Gas side pipe temp. Sensor Suction temp. Sensor Evaporator temp. Sensor<br />

Discharge temp. Sensor<br />

A unit P.M.V.<br />

B unit P.M.V.<br />

C unit P.M.V.<br />

* 2<br />

* 1 D unit P.M.V.<br />

• Error display<br />

• Signal communication to MCU<br />

* 2 4-Way valve<br />

Relay circuit<br />

• PWM synthesis function<br />

Clock frequency<br />

Outdoor<br />

fan<br />

motor<br />

Inverter<br />

(DC ® AC)<br />

Over current<br />

sensor<br />

Driver<br />

circuit of<br />

P.M.V.<br />

M.C.U<br />

• Inverter outdoor frequency control<br />

• A/D converter function<br />

• P.M.V. control<br />

• Discharge temp. control<br />

Rotor position<br />

detect circuit<br />

Gate drive<br />

circuit<br />

Over current<br />

detect circuit<br />

oscillator circuit<br />

16MHz<br />

Signal communication<br />

to MCU<br />

MCC-818 (SUB-P.C. B)<br />

A unit<br />

send/receive<br />

circuit<br />

B unit<br />

send/receive<br />

circuit<br />

C unit<br />

send/receive<br />

circuit<br />

D unit<br />

send/receive<br />

circuit<br />

* 1<br />

220–240V ~50Hz<br />

220V ~60Hz<br />

Noise filter<br />

Input current<br />

sensor<br />

Converter<br />

(AC ® DC)<br />

Clock frequency<br />

oscillator circuit<br />

10MHz<br />

High power factor<br />

correction circuit<br />

MCC-1438 (MAIN-P.C. B)<br />

M.C.U<br />

• PWM synthesis function<br />

• Input current release control<br />

• IGBT over current detect control<br />

• High power factor correction control<br />

• Signal communication to MCU<br />

• Output current release control<br />

• A/D converter function<br />

Over current<br />

sensor<br />

Over current<br />

detect circuit<br />

Inverter<br />

(DC ® AC)<br />

Gate drive<br />

circuit<br />

Output current<br />

sensor<br />

Compressor<br />

P.M.V : Pulse motor valve<br />

PWM : Pulse width modulation<br />

IGBT : Insulated gate bipolar<br />

transistor<br />

NOTE) ∗1 : 4 unit multi model only.<br />

∗2 : Heat pump model only.<br />

– 47 –